OVEM-…-LK
78
Festo – OVEM-…-LK – 1602NH English
11
Technical data
OVEM-...
-05
-07 / -10
-14 / -20
General
Approval
RCM
CE mark
(
è
www.festo.com/sp declaration of conformity)
In accordance with EU EMC Directive
Characteristic values
Operating pressure OVEM-...-QS / -GN / -PL
[bar]
2…6
Operating pressure OVEM-...-QO / -GO / -PO
[bar]
2…8
Pressure measuring range
[bar]
-1…0
Overload pressure at vacuum port
[bar]
5
Ready-state delay
[ms]
500
Dead time (evacuation and ejection)
[ms]
10
20
35
Electronics
Nominal operating voltage
[V DC]
24 ± 15 %
Max. output current (for all switching outputs)
[mA]
100
Voltage drop (for all switching outputs)
[V]
1.8
Idle current
[mA]
70
Coil characteristics, 24 V DC - low current phase
[W]
0.3
Coil characteristics, 24 V DC - high current phase
[W]
2.55
Time until current reduction
[ms]
80
Capacitive load maximum DC
[nF]
100
Overload protection
Provided
Inductive protective circuit
Adapted to MZ, MY, ME coils
Insulation voltage
[V]
50
Surge resistance
[kV]
0.8
Max. current consumption
In IO-Link mode
[mA]
150
In SIO-mode without master connection
[mA]
270
Accuracy
[% FS]
± 3
Hysteresis
[% FS]
± 0.1
Short-circuit resistance
Provided
Protection against incorrect polarity
For all electrical connections
Display/operation
Threshold value setting range
[bar]
-0.999…0
Hysteresis setting range
[bar]
-0.9…0
Environment
Ambient temperature
[°C]
0…50
Temperature of medium
[°C]
0…50
Operating medium
Compressed air in accordance with
ISO 8573-1:2010 [7:4:4]
Note on the operating medium