background image

2.1 Functions

Type

Symbol

Function

−QO/−GO−CN−

Ū

−1P/1N

NC  solenoid  valve  for  vacuum
ON/OFF  with  vacuum  sensor  and
silencer

Without  vacuum
sensor

NC  solenoid  valve  for  vacuum
ON/OFF  with  silencer

−QS/−GN−CN−

Ū

−1P/1N

NC  solenoid  valve  for  vacuum
ON/OFF  with  vacuum  sensor

Without  vacuum
sensor

NC  solenoid  valve  for  vacuum
ON/OFF

−QO/−GO−ON−

Ū

−−1P/1N

NO  solenoid  valve  for  vacuum
ON/OFF  with  vacuum  sensor  and
silencer

Without  vacuum
sensor

NO  solenoid  valve  for  vacuum
ON/OFF  with  silencer

−QS/−GN−ON−

Ū

−1P/1N

NO  solenoid  valve  for  vacuum
ON/OFF  with  vacuum  sensor

Without  vacuum
sensor

NO  solenoid  valve  for  vacuum
ON/OFF

−QO/−GO−CE−

Ū

−1P/1N

NC  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum",  with  vacuum  sensor  and
silencer

Without  vacuum
sensor

NC  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum",  with  silencer

Type

Symbol

Function

−QS/−GN−CE−

Ū

−1P/1N

NC  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum",  with  vacuum  sensor

Without  vacuum
sensor

NC  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum"

−QO/−GO−OE−

Ū

−1P/1N

NO  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum",  with  vacuum  sensor  and
silencer

Without  vacuum
sensor

NO  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum",  with  silencer

−QS/−GN−OE−

Ū

−1P/1N

NO  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum",  with  vacuum  sensor

Without  vacuum
sensor

NO  solenoid  valve  for  vacuum
ON/OFF,  solenoid  valve  for  ejector
pulse,  ejector  pulse  adjustable
using  adjusting  screw,  integrated
non−return  valve  for  maintain
vacuum"

Fig.3

Circuit  symbols  for  the  functions

2.2 Switching  output  and  switching  inputs

The  vacuum  is  monitored  with  the  aid  of  a  piezoresistive  sensor  element.  The  vac
uum  sensor  converts  pneumatic  pressure  values  and  supplies  electrical  signals.
When  the  taught  switching  point  is  reached,  the  vacuum  sensor  closes  a  circuit,
supplying  an  electrical  signal.  This  signal  can  be  used  for  control  functions.
The  vacuum  generator  can  be  connected  to  higher−level  systems  by  means  of  a
switching  output  (−1P,  1N)  and  switching  inputs.  The  switching  output  is  configured
as  normally  open.  The  output’s  switching  function  is  defined  as  a  threshold  value
comparator.
The  input  signals  determine  the  actuation  of  the  solenoid  valves  for  control  of  the
compressed  air  and  the  ejector  pulse.

ON

ON

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

Solenoid  valve 

1

Solenoid  valve 

2

Input  signal

Switching
position
of  solenoid  valve

Fig.4

Switching  characteristics  of  switching  inputs

Reviews: