22
Festo — MSE6-E2M — 2022-08d
Functions
Data field / function
Input word
1)
Output word
1)
Flow measurement
Measured value
Em.0
–
Consumption measurement
Measured value
Em.1
–
Function status
Em.3
–
Control/operation
–
Am.0
Pressure measurement
Measured value
Em.2
–
Pressure change measurement
Measured value
with selectable input data
5.2.3 Selectable input data function.
Blocking function
Function status
Em.3
–
Input data
–
Am.0
Selectable input data
Input address
Em.4
Am.1
Input data
Em.5
–
1) m = module number 1
Tab. 3: Overview of input data and output data
5.2.2
Description of the input data and output data
–
The input words and output words of all input data and output data are shown in the Motorola
format, MSB-LSB. If the control system uses a different byte order, this must be taken into account
in the user program.
–
The input words, 2 bytes, 16 bits, are sent to the higher-order controller.
–
The output words, 2 bytes, 16 bits, are sent from the higher-order controller.
5.2.2.1
Output word Am.0 module control
The consumption measurement and the blocking function are controlled in the Am.0 output word.
Data format of output word 16 bits, right-justified
D15
D14
D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
B15
B14
B13 B12 –
–
–
–
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Abbreviations used
B0
Shut-off valve controller
B1
Auto blocking