30
Festo — MS6(N)-SV-...-E-10V24 — 2021-11e
Technical data
12.5
Filling flow
Flow rate qn dependent on the number of rotations n of the flow control screw
p1 = 10 bar
p1 = 4 bar
p1 = 6 bar
p1 = 8 bar
Fig. 19: Flow diagram
12.6
Exhaust time
The following table shows the exhaust time in normal operation (N) and in the event of a fault (F) for
different volumes and operating pressures.
NOTICE
In the case of a fault (F) the worst possible fault in the valve’s interior is assumed (worst case).
Normal operation: N
Fault case: F
Operating pressure
3.5 bar
Operating pressure
6 bar
Operating pressure
10 bar
Exhaust time [s]
Exhaust time [s]
Exhaust time [s]
to 1.0 bar
to 0.5 bar
to 1.0 bar
to 0.5 bar
to 1.0 bar
to 0.5 bar
Volume [l]
2
N
0.1
0.2
0.24
0.3
0.3
0.4
(F)
(0.16)
(0.22)
(0.28)
(0.35)
(0.36)
(0.52)
10
N
0.3
0.45
0.55
0.7
0.7
0.9
(F)
(0.4)
(0.6)
(0.8)
(1.1)
(1.2)
(1.9)
20
N
0.5
0.85
1.0
1.3
1.4
1.7
(F)
(0.8)
(1.25)
(1.5)
(2.2)
(2.4)
(3.9)
40
N
1.2
1.9
2.2
3.0
3.0
3.9
(F)
(1.7)
(2.8)
(3.4)
(5.3)
(5.1)
(8.1)
150 N
3.2
5.0
6.0
8.2
11.0
12.8
(F)
(4.8)
(8.2)
(9.8)
(15.4)
(16.2)
(29.0)
Tab. 13: Exhaust time