6. Commissioning
104
© Festo Didactic 655633
6.10.4
Mitsubishi/MELSEC controller
•
Controller: Mitsubishi FX1N
•
Programming software: GX IEC Developer 6.01 or higher
1.
Connect PC and PLC using the RS232/RS422 programming cable with PC adapter
2.
Switch on power supply unit
3.
Switch on the compressed air supply
4.
Release the EMERGENCY-STOP pushbutton (if available)
5.
Overall reset PLC memory:
–
Wait until the PLC has carried out its test routines.
CPU FX1N
–
Turn the mode selector switch to STOP.
–
Start the PLC programming software.
–
Select
Online
PLC Clear
All
and confirm with
Yes
.
–
The memory reset is completed.
–
The PLC is ready for program download.
6.
Restore the file
04_HA_AS.pcd
from the directory Sources\PLC Programs\
Release C\FX1N of the CD-ROM supplied
Extras
Project Restore
…
select a project file (CD ROM: Sources\PLC Programs\Release C\FX1N)
04_HA_AS.pcd
Open
Select destination directory
OK
Confirm the following note (“After saving,…”) with
OK
Summary of Contents for MPS Station
Page 1: ...655633 de en 07 18 R2 6 Station Handhaben Handbuch Handling station Manual CD ROM included ...
Page 14: ...3 Technische Daten 14 Festo Didactic 655633 ...
Page 16: ...4 Transport Auspacken Lieferumfang 16 Festo Didactic 655633 ...
Page 26: ...5 Aufbau und Funktion 26 Festo Didactic 655633 ...
Page 52: ...6 Inbetriebnahme 52 Festo Didactic 655633 ...
Page 54: ...7 Wartung 54 Festo Didactic 655633 ...
Page 58: ...Aktualisierungen 58 Festo Didactic 655633 ...
Page 66: ...1 Introduction 66 Festo Didactic 655633 ...
Page 68: ...2 Notes on safety 68 Festo Didactic 655633 ...
Page 70: ...3 Technical data 70 Festo Didactic 655633 ...
Page 72: ...4 Transport Unpacking Scope of delivery 72 Festo Didactic 655633 ...
Page 82: ...5 Design and function 82 Festo Didactic 655633 ...
Page 108: ...6 Commissioning 108 Festo Didactic 655633 ...
Page 110: ...7 Maintenance 110 Festo Didactic 655633 ...
Page 114: ...Updates 114 Festo Didactic 655633 ...
Page 115: ......