Valve terminal MPAC-VI
with I-Port/IO-Link interface

Festo AG & Co. KG

Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com

Brief description
(Original instructions)

8073671
2017-07a
[8073673]

Valve terminal MPAC-VI with I-Port/IO-Link interface

English

. . . . . . . . . . . . . . . . .

IO-Link® is a registered trademark of the trademark holder in certain countries.

1

About this document

This document describes the I-Port/IO-Link interface of the valve terminal.
Additional aspects of use are described in other documents and must be observed

è

 1.1 Further applicable documents.

1.1 Further applicable documents

Document

Table of contents

Description  MPAC-VI

Detailed description of installation, commis­
sioning, maintenance and conversion of the
valve terminal

Description/brief description/operating in­
structions CTEU-...

Detailed description of the bus node, which can
be connected in a decentralised way to the
valve terminal

Assembly instructions MPA-C

Mounting methods of the valve terminal

Additional assembly instructions

Mounting of valve terminal components

Fig. 1

For all available product documentation 

è

 www.festo.com/pk

2

Safety

2.1 General safety information

Warning

Danger of injury through uncontrolled movements of connected devices. Make
sure that electrical and pneumatic equipment are in a de-energised and pressure­
less status.
Before working on the pneumatics:
 Switch off the compressed air supply
 Exhaust the valve terminal
Before working on the electrical components, e.g. before installation or mainten­
ance work:
 Switch power supply off
In this way, you avoid:
– sudden uncontrolled movements of loose tubing
– accidental and uncontrolled movements of the connected actuators
– undefined switching statuses of the electronics.
– functional damage.

Note

– Installation and commissioning must be carried out only by authorized quali­

fied personnel.

– The components of the valve terminal include electrostatically sensitive ele­

ments. The components could be damaged if you touch the contact surfaces
of the plug connectors or if you do not observe the handling specifications for
electrostatically sensitive devices.

 Do not exceed the specified limits in the technical data.
 Start up only a completely mounted and wired valve terminal in order to avoid

uncontrolled movements of detached tubing lines (whip effect) or impair­
ments caused by unlocked pneumatic connections.

2.2 Use for intended purpose

The valve terminal has been designed exclusively for controlling pneumatic actuat­
ors. It is intended for installation in machines or automation technology systems
and must be used exclusively as follows:
– in an industrial environment; outside of industrial environments, e.g. in commer­

cial and mixed-residential areas, actions to suppress interference may have to
be taken.

– within the limits of the technical data,
– in the original status, without unauthorised modifications,
– in excellent technical status.
Use for intended purpose is described completely in the documentation. Every
other use is considered not intended.

2.3 Training of specialized personnel

The product may be commissioned only by an electrotechnically qualified person,
who is familiar with the following topics:
– installation and operation of control and automation systems
– applicable regulations for operating safety-engineering systems
– applicable regulations for accident prevention and occupational safety
– documentation for the product

3

Further information

– accessories 

è

 www.festo.com/catalogue

– spare parts 

è

 www.festo.com/spareparts

4

Service

Contact the regional Festo contact if you have technical questions

è

 www.festo.com.

5

Product design

5.1 Display and control elements

There is an LED and a manual override (MO) for each solenoid coil. The LED and MO
for the corresponding solenoid coil are arrayed as follows:

1

2

2

1

1

LED and manual override for valve
solenoid coil 14

2

LED and manual override for solen­
oid coil 12

Fig. 2

5.2 Power supply

Note

 Only use PELV circuits in accordance with IEC/EN 60204-1 for the electrical

power supply (protective extra-low voltage, PELV).

 Observe also the general requirements for PELV power circuits in accordance

with IEC/EN 60204-1.

 Only use voltage sources which ensure reliable electrical isolation of the oper­

ating voltage in accordance with IEC/EN 60204-1.

 Always connect both circuits for operating and load voltage supply.

Through the use of PELV circuits, protection against electric shock (protection
against direct and indirect contact) is ensured in accordance with IEC/EN 60204-1.

5.3 Connecting cable

Note

– Long electric connecting cables reduce the resistance to interference. Use

connecting cables with a length of max. 30 m.

 Use the connecting cables NEBC-C-S1WA9-F-... for the valve terminal from the

Festo accessories. In this way, you ensure that protection class IP69k is ful­
filled.

5.4 I-Port/IO-Link interface

The valve terminal can be connected as follows via the connecting cable:
– to an external I-Port interface
– to an IO-Link master (

è

 Chap. 7.1)

– to a decentralised CTEU bus node
Depending on the configuration of your valve terminal, the I-Port/IO-Link interface
(

è

 Fig. 3) is on the valve side (front side) or the connection side (reverse side) of

the left end plate.