Fault description
Cause
Remedy
Cover strip has waves.
Wear on the belt reversal device
or incorrectly tensioned cover
strip
Retension cover strip
è
Particle friction on axis
Wear on the belt reversal device
or incorrectly tensioned cover
strip
–
Retension cover strip and if
there is considerable wear,
replace the
belt reversal device and
cover strip
–
Reduce the speed.
Toothed belt wear
Wear
Send axis to Festo or contact
the local Festo service.
Tab. 6
11.2
Repair
Send the product to the Festo repair service for repair.
12
Disassembly
WARNING!
Unexpected movement of components.
Injury due to impacts or crushing.
•
Before working on the product, switch off the control and secure it to prevent it from being
switched back on accidentally.
1. Observe transport information
è
2. Remove power and data cables as well as retaining screws.
If repairs are required:
•
Send axis to Festo or contact Festo service
è
Festo carries out the required repairs, fine adjustments and checks.
Information about spare parts and accessories
è
13
Disposal
ENVIRONMENT!
Send the packaging and product for environmentally sound recycling in accordance with the current
regulations
è
Disassembly
15
Festo — ELCC-TB-KF — 2018-05