WARNING

Danger of burns from hot housing surfaces.
Metallic housing parts can reach high temperatures during operation.
Contact with metal housing parts can cause burn injuries.
• Do not touch metallic housing parts.
• After the power supply is switched off, let the device cool down to room

temperature.

Updating device data (only via IO-Link)
• Firmware update
• Updating parameter set
• Data backup (Data Storage)

è

 "Integrated drive EMCS" instruction manual 

è

  www.festo.com/sp

8.1

Commissioning: DIO operation (digital I/Os)

Preparation:
1. Check mounting of the drive system.
2. Check wiring of the power supplies and the "DI/DO" digital inputs and out-

puts at the [Power] and [Logic] connections.

Procedure:
1. Switch on load voltage.
2. Switch on logic voltage (switch-on delay ≥50 ms required). If the logic voltage

is switched on before the load voltage, the EMCS-ST starts with an error that
must be acknowledged.

3. Wait for initialisation until C/Q LED is yellow (

L

 7 s).

4. Select the reference end position "Ref" from the HMI interface in the "Refer-

ence" menu and start the homing with end position detection (only required
if the reference end position "Ref" is different from the factory setting or if
the useful range has been changed). The drive system is referenced after a
successful homing.

Referencing sets the start press position "Pos

Start Press

" equal to the calculated

useful range.

5. Parameterise operating modes via HMI interface:

Basic parameters for point-to-point operation with and without press function
or manual operation (demo)

Velocity "Speed Out"

Velocity "Speed In"

additional parameters for point-to-point operation with press function

"Force"

Start Press "Pos

Start Press

" position (reference point end position "Ref")

The EMCS-ST is then ready for operation and the application can be controlled via
the "DI/DO" digital inputs and outputs 

è

 9.6 Point-to-point operating modes.

8.2

Commissioning: IO-Link operation

Preparation
1. Check mounting of the drive system.
2. Check the wiring of the power supplies and the IO-Link "C/Q" interface at the

[Power] and [Logic] connections.

Procedure
1. Switch on load voltage.
2. Switch on logic voltage via IO-Link master (switch-on delay ≥50 ms required).

If the logic voltage is switched on before the load voltage, the EMCS-ST starts
with an error that must be acknowledged.

3. Wait for initialisation until C/Q LED is yellow (

L

 7 s).

4. Select the reference end position "Ref" from the IO-Link device data

(0x0103.0, reference) and start the homing with end position detection
(0x0104.0, Execute "Reference" Movement) (only required if the reference
end position Ref" is different from the factory setting or if the useful range
has been changed). The drive system is referenced after a successful homing.

Homing sets the "Pos

Imp

" intermediate position and the "Pos

Start Press

" start

press position equal to the determined useful range.

5. Parameterise operating modes via IO-Link interface:

Basic parameters for point-to-point operation with and without press function
or manual operation (demo)

0x0100.0, velocity "Speed In"

0x0101.0: velocity "Speed Out"

0x0106.0, end position "Out" "Lim

Out

" (reference point reference end posi-

tion "Ref")

0x0108.0, intermediate position "Pos

Imp

" (reference point reference end

position "Ref")

additional parameters for point-to-point operation with press function

0x0102.0, Force "Force"

0x0105.0, start press position "Pos

Start Press

" (reference point reference end

position "Ref")

Then the EMCS-ST is ready for operation and the application can be controlled
via the IO-Link interface "process data 0x0029.1, 0x0029.2 and 0x0029.5" or
"system parameter 0x0002" 

è

 9.6 Point-to-point operating modes.

9

Operation

WARNING

Danger of burns from hot housing surfaces.
Metallic housing parts can reach high temperatures during operation.
Contact with metal housing parts can cause burn injuries.
• Do not touch metallic housing parts.
• After the power supply is switched off, let the device cool down to room

temperature.

9.1

Master control

Lowest priority: DIO operation (after Power ON and initialisation)

Medium priority: IO-Link operation (after established IO-Link communication)

Highest priority: HMI operation (unlocked pushbuttons)

9.2

Dimension reference system

The correct positioning of the drive requires a defined dimension reference
system.

Linear drive system

Ref 

: reference end position (reference point for Lim

In

, Lim

Out

, Pos

Act

, Pos

Imp

 and Pos

Start Press

)

motor facing (default)

motor facing away

Lim

In

/Lim

Out

 

: end positions

Mech

In

/Mech

Out

: mechanical stops

Pos

Act

  : current position

Pos

Imp

: intermediate position (IO-Link only)

Pos

Start Press

: Start Press position

Tab. 3: Dimension reference system for linear drive systems

9.3

Restart with homing

Re-initialise reference end position "Ref"
The referencing of the reference end position is lost on Power OFF of the logic
voltage L

+

 [Logic, Pin 1]. After every restart the position of the reference end

position "Ref" is re-initialised at the "Speed Ref" velocity with the first motion
task.

Summary of Contents for EGSS-BS

Page 1: ... personnel have knowledge and experience in dealing with electric drive systems 3 Additional information Contact the regional Festo contact if you have technical problems è www festo com Accessories and spare parts è www festo com catalogue 4 Product overview 4 1 Scope of delivery The following components are included in the scope of delivery Mini slide unit EGSS Instruction manual for the mini sl...

Page 2: ...he logic power supply 3 Integrated drive EMCS ST 4 Higher level controller with dig ital I O Status and control signals The following table shows the status and control signals and the electrical levels of the digital inputs and outputs as a function of the PNP NPN version of the integrated drive Status and control signal Electrical levels PNP positive logic NPN negative logic 0 Low level 0 V High...

Page 3: ...erence end position Ref from the IO Link device data 0x0103 0 reference and start the homing with end position detection 0x0104 0 Execute Reference Movement only required if the reference end position Ref is different from the factory setting or if the useful range has been changed The drive system is referenced after a successful homing Homing sets the PosImp intermediate position and the PosStar...

Page 4: ...tartRef PosAct è LimIn è LimOut press Run Start Press movement Start Stop and save Start Press Position PosStart Press Save press Execute demo run Start Stop Lock pushbutton actuators Lock HMI press and hold for 3 s or no push button actuator input for 15 s To acknowledge an error press and hold for 3 s Reset to factory settings press and simultaneously for 10 s and then carry out a Power OFF ON o...

Page 5: ...y Speed Out 0x0101 0 Speed Out1 Velocity Speed In 0x0100 0 Speed In1 Force Torque 0x0102 0 Force1 2 Start Press Position PosStart Press 0x0105 0 Position Start Press mm 2 3 4 End position LimOut 0x0106 0 end position Out mm 4 Intermediate position PosImp 0x0108 0 Intermediate Position mm 3 4 Control point to point operation via digital inputs Positioning task Control signals MovIn DI1 Logic Pin 5 ...

Page 6: ...too high 0x400 0 Remedy Check ambient conditions Check installation condi tions 0x012F 303 IO Link connection inter rupted IO Link connection inter rupted z Remedy Check power supply Check IO Link master 1 Additional information è Instruction manual for integrated drive EMCS ST 2 This error can only be acknowledged by a restart Tab 7 Information Warnings and Errors diagnostic messages 10 1 Repair ...

Page 7: ... 24 Logic current consumption logic pin 1 mA DIO operation 100 300 IO Link operation 100 150 Load current consumption power pin 1 A 3 3 5 3 IO Link port class A IO Link protocol version Device V 1 1 1 Maximum value for Speed In Speed Out at level 10 2 Unchangeable parameter 3 Maximum value for Force at level 10 4 Force is controlled and evaluated by closed loop control of the motor current Dependi...

Reviews: