EGC-TB-KF, EGC-HD-TB
Festo – EGC-TB-KF, EGC-HD-TB – 2017-11c English
13
8
Maintenance and care
Warning
Uncontrolled moving masses can cause injury to people or damage to property (squeez
ing). If a toothed belt breaks in combination with a vertically or diagonally installed EGC,
the work mass will fall down.
In case of signs of wear, return the EGC to Festo for repairs.
Controller signals can cause the EGC to make unintended movements.
Switch off the controller for all maintenance work on the EGC and secure it to pre
vent it from being restarted unintentionally.
On cleaning and maintenance:
If required, clean the guide axis with a soft cloth. All media gentle to the material may be used as
cleaning agents.
Note
The lubrication interval S
int
is dependent on the product load.
Cut the lubrication interval S
int
(
è
Fig. 12) in half if the following situations are
present:
–
dusty and dirty environment
–
nominal strokes
2000 mm
–
at speeds
2 m/s
–
positioning profile
Z
delta operation (frequent acceleration and braking)
–
ambient temperatures
40 °C
–
product has been in operation for
3 years.
If several situations occur simultaneously, the lubrication interval must be divided by
four.
Grease the following components:
Bearing guide
Guide rail
Lubricating point (
è
Relubrication opening
aB
Surface
5
Lubrication interval
(
è
As required
1)
Grease
2)
Roller bearing grease
1)
or if the component no longer has a layer of grease
2)
Grease gun, blast pipe and grease (
è
Tab. 6