12
Technical data
Size
1)
20
50
100
Design
Electric stopper cylinder
Mounting position
1)
Any
Maximum stoppable load at transport speed v
F
– V
F
= 6 m/min
[kg]
0.25 … 20
1 … 50
3 … 100
– V
F
= 9 m/min
[kg]
0.25 … 10
1 … 35
3 … 70
– V
F
= 12 m/min
[kg]
0.25 … 7
1 … 30
3 … 60
– V
F
= 18 m/min
[kg]
0.25 … 3.5
1 … 18
3 … 50
– V
F
= 24 m/min
[kg]
0.25 … 2.5
1 … 12
3 … 45
– V
F
= 30 m/min
[kg]
0.25 … 2
1 … 8
3 … 30
– V
F
= 36 m/min
[kg]
0.25 … 1
1 … 5
3 … 20
– Friction coefficient
ì
0.1 between transported material
and belt system
0.07 between
transported
material and
roller system
Cushioning length
[mm]
11.5
17.5
18.2
Max. lateral force
[N]
20
50
100
Max. time for retracting
2)
[s]
0.1
0.15
0.3
Max. time for extending
[s]
0.1
0.15
0.2
Max. cycle rate
[Hz]
0.33
Ambient temperature
[°C]
–10 … +60
Storage temperature
[°C]
–20 … +60
Degree of protection
IP40
Power supply
[V DC]
24 ± 15 %
Max. current consumption
3)
(actuator)
[A]
1.9
1.2
1.4
Max. current consumption
(sensor)
[A]
0.3
Max. cable length
[m]
30
Digital inputs
Switching logic
PNP
Switching level
[V]
>
19 (1-signal)
<
8 (0-signal)
Digital outputs
Max. output current per
switching output
[mA]
30
Switching logic
PNP
Voltage drop
[V]
<
1 (1-signal)
Short circuit protection
No
CE marking (
è
declaration
of conformity)
è
www.festo.com/sp
in accordance with EU EMC Directive
4)
Weight
[g]
420
800
985
Note on materials
PWIS
5)
-containing substances
Materials
Housing
Wrought aluminium alloy, hard-anodised
Cover
PA reinforced
Piston rod
High-alloy stainless steel
Screws, stop
Coated steel
Glide element, blanking plug
PE
Fibre-optic cables
PC
Plug connector
CuZn, nickel-plated (pin contacts: gold-plated)
Seals
NBR
1) Stopper is intended for use in transfer systems. The technical specifications apply for the horizontal direc-
tion or movement in which the stopper is aligned lying flat or standing.
2) without lateral force
3) During the switch-on process, there is briefly a larger starting current.
4) This product can generate high frequency interference, which may make it necessary to implement interfer-
ence suppression measures in residential areas.
5) PWIS - paint-wetting impairment substances
Tab. 7