9. EasyPort USB command interpreter
142
© Festo Didactic GmbH & Co. KG „ 721876
142
The commands for reading and writing digital signals are summarised in
the following tables.
Modify
command
Resource
Data type
Address
Examples and comments
M
(modify)
A
(output)
(bit)
0...15
MA1.0.4=1
Change output bit 4 from word 0 at
EasyPort USB module 1 to 1.
The data value for modify commands can
only be specified in hexadecimal format.
B
(byte)
0
,
1
MAB2.0.0=7
Change output byte 0 from word 0 at
EasyPort USB module 2 to 7 hexadecimal.
This means:
bit 0, bit 1 and bit 2 are set.
Lower order: byte 0 (port 1)
Higher order: byte 1 (port 2)
W
(word)
0
MAW1.0=101
Change output word 0 at EasyPort USB
module 1 to 101 hexadecimal or 257
decimal.
9.5
Commands for
digital signals
Summary of Contents for EasyPort USB D16A
Page 1: ...721876 DEENESFR EasyPort USB Manual CD ROM included ...