DSMI-B
Festo DSMI-B 2017-12d English
11
6. Repeat the adjustment for the other end position.
7. Press the cover cap of the DSMI back on
to the snap ring of the housing
(if present).
The cover cap can also be snapped on to
freely positioned shock absorber retainers
if the elements are broken through at the
predetermined breaking point.
Check whether additional shock absorbers or stops are necessary.
Additional shock absorbers or stops are necessary in the following cases:
– For moving masses with a mass moment of inertia greater than the
determined permitted mass moment of inertia
– When the DSMI is operated without an air cushion on the exhaust side
(e.g. after long breaks between the individual swivel movements).
Adjusting the DSMI with internal stop system
When external stops and shock absorbers are used:
Make sure that the following
specifications are complied with:
– Point of impact in the mass moment of
inertia (important for eccentric masses
on the lever arm)
– Max. permissible stop force
– Minimum stop radius r
min
(
è
Technical data)
– Using protective devices (e.g. cover cap
è
Accessories)
Fig. 15
Fig. 16