DNCE−...−LAS
Festo DNCE−...−LAS 1003b English
30
Protecting the end positions against uncontrolled overrunning:
S
bear in mind the fact that software end positions must be set in the SFC−LACI
controller.
S
Make sure that the SFC−LACI controller is voltage−free.
It is not sufficient just to cancel the enable signal to the controller.
S
Connect the DNCE−LAS to the controller at
connection
5
Additional earthing of the DNCE−LAS is
not necessary.
S
Use the original Festo connector cables in
accordance with the Accessories"
chapter.
1. Unscrew the cover screws and lift off the
housing cover (A).
2. Wire up the sensor and motor plug con
nectors in accordance with the table below.
3. Use the cable terminal (B) to ensure strain
relief for the cables.
4. Re−fasten the housing cover without
pinching (tightening torque of the cover
screws: 0.6 Nm).
Pin
Cable colour
Designation
Function
Pin allocation
1
red
U
U string
2
3
2
green
V
V string
1
2
3
4
3
black
W
W string
1
4
4
n.c.
reserved
Black plug
1
blue
U/
U/ string
2
3
2
yellow
V/
V/ string
1
2
3
4
3
white
W/
W/ string
1
4
4
n.c.
reserved
Black plug
Fig.4
5
Fig.5
(A)
(B)
Fig.6
(B)