DGC-8/12
Festo DGC-8/12 0212NH English
25
v [m/s]
m [kg]
aH
DGC-12-...
aG
aI
aF
bJ
bA
r
0
= 35 mm
aF
DGC-12-G with elastomer absorbers
aG
DGC-12-G with shock absorb. type YSR
aH
DGC-12-G with shock absorber type
YSRW
aI
DGC-12-KF with elastomer absorbers
bJ
DGC-12-KF with shock abs. type YSR
bA
DGC-12-KF with shock absorber type
YSRW
Fig. 22 and Fig. 23:
Maximum slide speed values as a factor of the distance of the
centre of gravity r
0
and the work load m at 6 bar, 20 degrees centigrade.
S
Close the one-way flow control valves
– at first completely,
– then loosen them one turn.
If there has been a conversion from lubricated to non-lubricated compressed air:
Please note
There will be an increase in wear as the service life lubrication has been washed
out.
S
The DGC-... must be completely lubricated again (permitted greases see
chapter 8).
Fig. 24