![Festo DDLI-25 Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/festo/ddli-25/ddli-25_operating-instructions-manual_2283389017.webp)
DDLI25_63
Festo –
DDLI25_63
– 2019-05b English
17
Permissible force and torque loading
Size
25
32
40
63
Fzmax
[N]
330
480
800
1600
Mxmax
[Nm]
1.2
1.9
3.8
5.7
Mymax
[Nm]
20
40
60
150
Mzmax
[Nm]
3
5
8
24
Formula for combined loads:
0, 4x
|Fz|
Fz
max
)
|Mx|
Mx
max
)
|My|
My
max
)
0, 2x
|Mz|
Mz
max
v
1
|Mz|
Mz
max
v
1
|Fz|
Fz
max
v
1
Tab. 10
Electrical data for all sizes
Displacement encoder
Magnetostrictive, contactless, absolute measuring,
digital
Protection class (measuring
system incl. housing and
connection technology)
IP67 (with correctly mounted plug socket with cable)
Electrical connection
Cable with 5-pin plug, round design M9
Cable length
[m]
1.5
Interface
CAN to ISO/DIS 11898
Transmission rate
[Mbps]
1
Linearity error (with reference
to the maximum stroke)
[%]
± 0.02 F. S. (min. ± 50
ì
m)
Repetition accuracy
[mm]
± 0.01 (up to 1000 mm stroke)
± 0.02 (1001 … 2000 mm stroke)
Supply voltage
[V DC]
24 (± 25 %)
Current consumption
[mA]
Typically 100
Temperature coefficient
15 ppm/°C
CE marking (declaration of
conformity
è
www.festo.com)
to EU EMC Directive
1)
In combination with CPX-CMIX. For specifications on repetition accuracy with end-position controllers or positioning controllers, see
respective description
Tab. 11