Technical data

Mechanical, pneumatic

Size

25

32

40

63

Pneumatic connection

G1/8

G1/8

G1/4

G3/8

Mode of operation

Double-acting

Position sensing

with integrated displacement encoder

Mounting position

Any

Operating medium

Compressed air in accordance with ISO 8573-1:2010

[6:4:4]

Note on the operating medium

Operation with lubricated medium not possible

Operating pressure

[bar]

2 … 8

Ambient temperature

[°C]

–10 … +60

Theoretical force at 6 bar

[N]

295

483

754

1870

Speed

[m/s]

0.05 … 3

0.04 … 3

0.04 … 3

0.03 … 3

Cushioning

Elastic cushioning rings/pads at both ends

Max. impact energy in the end

positions

[Nm]

0.05

0.12

0.25

0.5

Note on materials

Free of copper and PTFE

Information on materials

Cylinder barrel, cover, slide

Anodised aluminium

Belt reverser

POM

Cover strip

Steel

Seals

NBR, TPE-U (PU)

Product weight

At 0 mm stroke

[kg]

1.10

1.72

2.58

8.73

per 10 mm stroke

[kg]

0.034

0.043

0.058

0.139

Tab. 9

Summary of Contents for DDLI-25

Page 1: ...Operating instructions 8113360 2019 05b 8113362 Linear drive DDLI 25_63...

Page 2: ...or serious injuries Caution Hazards that can cause minor injuries Other symbols Note Material damage or loss of function Recommendations tips references to other documentation Essential or useful acc...

Page 3: ...nd storage 5 4 Requirements for use 6 5 Installation 7 5 1 Installation mechanical 7 5 2 Installation pneumatic 10 5 3 Installation electric 11 6 Commissioning 12 6 1 Commissioning the complete system...

Page 4: ...ting blue releasing ring 3 Earthing e g via screws 4 in the connection cap 4 Screws with female thread for attachment of the drive 4x per side 5 Slide 6 Mounting thread for useful load 7 Cylinder barr...

Page 5: ...X CMAX measuring module CPX CMIX The linear drive DDLI in intended for the pneumatic positioning of loads in slide operation The DDLI is intended for use in an industrial environment Outside of indust...

Page 6: ...nagement of electronic compon ents Take into account the material specifications Technical data Use the product in its original status without any unauthorised product modifications Take into consider...

Page 7: ...in Damage to the sealing band reduces its reliability in operation Jerky movement of the unpressurized slide can cause a partial vacuum that sucks the sealing band into the piston chamber Fig 2 Avoid...

Page 8: ...ounting screws in lightly 2 Place the central supports over the slot nuts in the mounting slot 3 Screw in the mounting screws lightly at first so that the central supports can still be moved 4 Move th...

Page 9: ...If the slide 5 becomes bent against a buckled use ful load the service life of the guide will be reduced Make sure the mounting surface of the useful load is even Fig 6 Note the tightening torques wh...

Page 10: ...ing down Check whether safety measures are required to prevent slow sinking as a result of leakage e g toothed latches or moveable bolts Connect the tubing connections in the supply ports The threaded...

Page 11: ...r setting the speed and in addition external stops Fig 8 5 m 5 3 Installation electric Wire the DDLI to the earth potential The internal thread A of the cover screws can be used for this purpose for e...

Page 12: ...ossible to touch the DDLI until the load has come to complete rest Warning Without external cushioning the DDLI may be damaged if the specified loads and speeds are exceeded drive specific information...

Page 13: ...es If used as a measuring cylinder no stroke reduction is required Fig 11 Size 25 32 40 63 Stroke reduction r mm 25 25 35 35 Tab 7 For use with SPC11 CPX CMPX Make sure that the external end stops are...

Page 14: ...belt system Clean the belt system as required with a soft cloth Avoid cleaning agents which will damage the belt system PU Excessive friction or grease solvent cleaning agents e g soap suds will damag...

Page 15: ...tructions on fault correction in the documentation for your controller Heavy leakage Linear module integrated in a distorted manner Fasten the linear actuator to a flat base Seal worn Return to Festo...

Page 16: ...n with lubricated medium not possible Operating pressure bar 2 8 Ambient temperature C 10 60 Theoretical force at 6 bar N 295 483 754 1870 Speed m s 0 05 3 0 04 3 0 04 3 0 03 3 Cushioning Elastic cush...

Page 17: ...echnology IP67 with correctly mounted plug socket with cable Electrical connection Cable with 5 pin plug round design M9 Cable length m 1 5 Interface CAN to ISO DIS 11898 Transmission rate Mbps 1 Line...

Page 18: ...DDLI 25_63 18 Festo DDLI 25_63 2019 05b English...

Page 19: ...DDLI 25_63 Festo DDLI 25_63 2019 05b 19...

Page 20: ...zation is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo SE Co KG Ruiter Stra e 82 73734 E...

Reviews: