background image

Bus node
CPX-FB39

Festo 

SE

 & Co. KG

 

Ruiter Straße 82

 

73734 Esslingen

 

Germany
+49 711 347-0
www.festo.com

Brief description
Translation of the original instructions

8101652
2018-11a
[8101654]

Bus node CPX-FB39

English

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

For all available product documentation 

è

 www.festo.com/pk

1

Intended use

The module described in this document is intended for use as a participant in a
Sercos-III network in an industrial environment. Outside of industrial environ­
ments, e.g. in commercial and mixed-residential areas, actions to suppress inter­
ference may have to be taken.
The module is intended exclusively for use in CPX terminals from Festo for
installation in machines or automated systems and may be used only in the
following ways:
– in an excellent technical status
– in original status without unauthorised modifications, except for the adapta­

tions described in this documentation

– within the limits of the product defined through the technical data.

You can find detailed information in the module description
(

è

 P.BE-CPX-FB39-...) and in the CPX system description

(

è

 P.BE-CPX-SYS-...).

2

Safety

This documentation is directed exclusively at technicians trained in control and
automation technology.

Warning

Electrical voltage
Injury caused by electric shock, damage to machine and to system
 For the electrical power supply, use only PELV circuits in accordance with

IEC 60204-1 (Protective Extra-Low Voltage, PELV).

 Observe the general requirements of IEC 60204-1 for PELV circuits.
 Use only voltage sources which guarantee reliable electrical isolation of the

operating and load voltage in accordance with IEC 60204-1.

 Always connect all circuits for operating and load voltage supplies U

EL/SEN

,

U

VAL

 and U

OUT

.

Note

Electrostatically sensitive devices
 Do not touch any components.
 Observe the handling specifications for electrostatically sensitive

devices.

Note

 Take into consideration the specifications and notes in the module description

and the assembly instructions for the components.

 Commission the module only if fully mounted and wired.

SERCOS

®

 is a registered trademark of its respective trademark holder in

certain countries.

3

Connection and display components

1

2

3

4

5

1

Rating plate

2

Network/CPX-specific LEDs

3

Network connections X1 and X2

1)

4

Cover for DIL switches

5

Service interface CPX-MMI or
CPX-FMT

2)

1)

Connection socket: M12, D-coded, 4-pin

2)

Connection socket: M12, A-coded, 5-pin

Fig. 1

3.1 Network connections

Socket

Connection [X1]

Connection [X2]

Pin

Signal/explanation

Pin

Signal/explanation

M12, 4-pin

1
2
3
4
Housing

TX+
RX+
TX–
RX–
FE

Transmitted data +
Received data +
Transmitted data –
Received data –
Screening/F E

1)

1
2
3
4
Housing

RX+
TX+
RX–
TX–
FE

Received data +
Transmitted data +
Received data –
Transmitted data –
Screening/F E

1)

1)

The screened connection is connected to the earth potential of the CPX terminal through an RC element.

Fig. 2

3.2 LED indicators - normal operating status

Behaviour of the LED indicators in normal operating status:
– The LEDs S, SD, PS and PL illuminate green.
– The LEDs TP1 and TP2 illuminate or flash green.
– The yellow LED (M) illuminates, flashes or is dark.
– The red LED (SF) is dark.

Network-specific LED indicators

CPX-specific LED indicators

2)

S (green, orange, red)

Sercos III

1)

PS (green)

Power System

SD (green, orange, red) Sub Device

1)

PL (green)

Power Load

TP1 (green)

Traffic Port 1

SF (red)

System Failure

3)

TP2 (green)

Traffic Port 2

M (yellow)

Modify

4)

1)

Detailed information (

è

 Description for the module P.BE-CPX-FB39-…)

2)

Detailed information (

è

 CPX system description P.BE-CPX-SYS-…)

3)

Flashes in case of error, error diagnostics (

è

 CPX system description P.BE-CPX-SYS-…)

4)

Parameterisation revised or “Force” active.

Fig. 3

4

Mounting and dismantling

Warning

Electrical voltage
Injury caused by electric shock, damage to machine and to system
 Switch supply power off before assembly work.

2

3

1

1

Screws

2

Module

3

Interlinking block

Fig. 4