10
Festo — CPX(-M)-FB33/34/35/43/44/45 — 2022-05f
Product overview
Description
Remote I/O
Remote controller
1: ON
2: OFF
I/O diagnostics interface
switched on.
Data field size:
32 bytes I/32 bytes O
1: ON
2: ON
Position is reserved.
Position is reserved.
Tab. 6: Setting the diagnostics mode
Reserved DIL switches are blocked for future functions and must not be used.
The setting of the DIL switches for operating mode and diagnostics mode must match the settings in
the open-loop control.
Memory card
The bus nodes CPX-(M)-FB43/44/45 do not support memory cards.
The memory card holds configuration data for the PROFINET addressing:
–
Fieldbus device name
–
IP address
The configuration data can be transferred to the new bus node with the memory card when replacing a
bus node.
The data on the memory card have priority over other configuration data. e.g. data stored in the bus
node memory or in the control system.
NOTICE
Malfunction or Damage to the Memory Card.
Inserting or removing the memory card while the power supply is switched on can result in malfunc-
tions of or damage to the memory card.
• Disconnect the power supply before you insert or remove the memory card.
The various bus node revisions are only compatible with the corresponding memory card:
Memory card
Bus bus node revision number
CPX-SK
from Rev 07
CPX-SK-2
from Rev 12
CPX-SK-3
from Rev 30
Tab. 7: Compatibility of the memory cards depending on the bus node revision