Festo — CPX-F8DE-P — 2022-10d
Diagnostics and error handling
6.3
Diagnostics using LEDs
The following LEDs for on-site diagnostics are located under the transparent covering of the module:
Fig. 35: LED display of the input module CPX-F8DE-P
NOTICE
The LED display of the input module is not designed for safety purposes.
• Please note that the LEDs should
not be used for evaluation for safety-related measures.
When the operating voltage supply U
EL/SEN
is switched on, the module error LED
1
lights for approx.
500 ms.
The FP-LED
2
flashes until the input module is correctly parameterised by a PROFIsafe master.
The following LEDs are on in the normal operating status:
–
FP LED
2
–
Status LEDs
4
of the active input channels
The status LEDs on inactive input channels and the module error LEDs
1
and channel error LEDs
3
do not light.