6
Diagnostics and error handling
Festo – P.BE-CPX-CMAX-SYS-EN – en 2017-09b – English
65
Possible status information
Status
display
Example
Description
Addi
tional
informa
tion
P
nn
Parameterisation active; additional information shows current
parameter nn in the form PNU/100 (PNU 400 becomes 04).
If a parameter is changed acycliclly or in the parameterisation
operating mode, the corresponding PNU is displayed as PNU/100
for the duration of 1 second. No display appears during read para
meter access or a parameter access over the diagnostic interface
(FCT CMAX plug-in).
If a new write parameter access is made within this display time
window, the new PNU is displayed as PNU/100 and the display
time begins again (1 second).
If in the parameterisation operating mode, no parameter has
been changed yet or the display time has expired, the additional
information will depict “--”.
E
nn
Error active (E); additional information shows error number nn
(here 72); description of the error numbers
è
0x:
configuration error
1x:
execution error
2x:
positioning record error
3x:
control error
4x:
system error A
5x:
system error B
6x:
error in the valve
7x:
error in the controller
8x:
error in the displacement encoder
“–”
flashes
“– –”
flashes
Device data reset.
To complete resetting, the CMAX must be switched off and back
on again.
1)
If the axis is not referenced:
Positive direction of movement: Starting position = 0 %, position mounting in % of cylinder length
Negative direction of movement: Starting position = 99 %, position trailing in % of cylinder length
Tab. 6.4
Status information display