background image

1

About this document

1.1

Applicable documents

All available documents for the product 

è

 www.festo.com/pk.

Document

Contents

Instruction manual for automation system
CPX-AP

Instruction manual and important information on
assembly, electrical installation and maintenance
tasks as well as description of the automation
system CPX-AP

Tab. 1 Applicable documents

1.2

Product version

This document refers to the following product versions:

Product

Version

CPX-AP-I-8DI-M8-3P

Digital input module CPX-AP-I-8DI-M8-3P revision 1 or later

Tab. 2 Product version

The product version can be identified from the product labelling.

There may be an updated version of this document for these or later product versions

è

 www.festo.com/sp.

1.3

Product labelling

The product labelling is located on the right-hand side of the module. The Data Matrix code is on the
connection side. Scanning the printed Data Matrix Code with an appropriate device opens the Festo
Support Portal with the information appropriate for the product. Alternatively, the Product Key
(11-digit alphanumeric code on the product labelling) can be entered in the search field of the Support
Portal 

è

 www.festo.com/sp.

About this document

Festo — CPX-AP-I-8DI-M8-3P — 2019-06

4

Summary of Contents for CPX-AP-I-8DI-M8-3P

Page 1: ...8099684 CPX AP I 8DI M8 3P Digital input module 8099684 2019 06 8099686 Instructions Operat ing ...

Page 2: ...Translation of the original instructions 2 Festo CPX AP I 8DI M8 3P 2019 06 ...

Page 3: ... 3 Training of qualified personnel 5 3 Additional information 5 4 Service 5 5 Product overview 6 5 1 Function 6 5 2 Configuration 7 5 2 1 Product design 7 5 2 2 LED displays 8 5 2 3 Connecting elements 8 6 Assembly 10 7 Installation 10 8 Commissioning 10 9 Parameterisation 10 10 Diagnostics and fault clearance 11 10 1 Diagnostic messages 11 10 2 LED displays 12 11 Disposal 13 12 Technical data 14 ...

Page 4: ... revision 1 or later Tab 2 Product version The product version can be identified from the product labelling There may be an updated version of this document for these or later product versions è www festo com sp 1 3 Product labelling The product labelling is located on the right hand side of the module The Data Matrix code is on the connection side Scanning the printed Data Matrix Code with an app...

Page 5: ...y for use in an automation system CPX AP Use the product only as follows Use only in an industrial environment Outside of industrial environments e g in commercial and residential mixed use areas it may be necessary to take measures to suppress radio interference Use only in combination with modules and components that are permissible for the respective product variant è www festo com catalogue On...

Page 6: ... LED indicators on the module and reported to the inter face via the system communication The sensor supply has an electronic fuse for protection against short circuit or overload If this elec tronic fuse responds the sensor supply of the module is switched off and the error is shown by an LED indicator on the module After the elimination of the short circuit or the overload the sensor supply is s...

Page 7: ...ion for input 6 X6 10 Connection for system communication forwarding XF20 11 Connection for system communication XF10 12 Connection for voltage forwarding XD2 13 Connection for power supply XD1 14 Mounting interface connection side bottom and connection functional earth FE 15 Mounting interface lateral bottom and connection for functional earth FE 16 Inscription label optional 17 Mounting interfac...

Page 8: ...6 X6 6 green 7 Status of input 4 X4 4 green 8 Status of input 2 X2 2 green 9 Status of input 0 X0 0 green Fig 2 LED displays 5 2 3 Connecting elements Connection for power supply XD1 Plug M8 4 pin A coded Signal 1 24 V DC logic supply PS 2 0 V DC load supply PL 3 0 V DC logic supply PS 4 24 V DC load supply PL Tab 4 Connection for power supply Product overview 8 Festo CPX AP I 8DI M8 3P 2019 06 ...

Page 9: ...mitted data 2 RX Received data 3 TX Transmitted data 4 RX Received data Tab 6 Connection for system communication Connection for system communication XF20 Socket M8 4 pin D coded Signal 1 RX Received data 2 TX Transmitted data 3 RX Received data 4 TX Transmitted data Tab 7 Connection for system communication Connection for inputs X0 X7 Socket M8 3 pin A coded Signal 1 24 V DC inputs 3 0 V DC input...

Page 10: ...after error free commissioning Information on troubleshooting in the event of incorrect behaviour è Instruction manual for automation system CPX AP è 10 Diagnostics and fault clearance 9 Parameterisation Various parameters are available for reading out information about the modules in an automation sys tem CPX AP and adapting the modules to the application situation Write access to the parameters ...

Page 11: ... short circuit overload of the sensor supply was detec ted Remedy Check connected load for correct function in particular for power consumption Check sensor and wiring 01 01 010B 16843019 Short circuit overload in sensor supply Diagnost ic status Error Undervoltage of the logic supply PS 24 V DC was detec ted Remedy Check logic supply PS 02 01 0016 33619990 Undervoltage in logic supply PS 24 V DC ...

Page 12: ...gree of severity Warning e g parameterisation error Take appropriate remedial action e g check parameterisation Illuminated red Module diagnostics active Degree of severity Error e g undervoltage in load supply PL Take appropriate remedial action e g check load supply PL LED flashes red quickly Module ramp up not yet completed System communication not yet initial ised Flashes quickly green Module ...

Page 13: ... 1 at input Off Input inactive logic 0 Logic 0 at input Tab 13 LED status of input 11 Disposal ENVIRONMENT Send the packaging and product for environmentally sound recycling in accordance with the current regulations è www festo com sp Disposal 13 Festo CPX AP I 8DI M8 3P 2019 06 ...

Page 14: ... code hex dec 0x2007 8199d Module identification CPX AP I 8DI M8 3P Degree of protection in accordance with EN 60529 IP65 IP67 if lines are connected and connections that are not required are closed with a cover cap Protection against elec tric shock protection against direct and indirect contact in accordance with IEC 61010 1 through the use of SELV PELV circuits safe extra low voltage protected ...

Page 15: ... PS V DC 24 25 Intrinsic current con sumption at nominal operating voltage 24 V from PS mA Typ 32 Diagnostic message undervoltage in logic supply PS V DC 18 Tab 15 Power supply Technical data 15 Festo CPX AP I 8DI M8 3P 2019 06 ...

Page 16: ...Sensor supply Sensor power supply SEN V DC 24 25 Voltage drop at short circuit protection reduction SEN V DC 1 Reverse polarity pro tection 24 V SEN against 0 V SEN oYes Potential difference between 0 V SEN external and 0 V SEN internal Not permissible Sensor power supply short circuit protection Short circuit protection Electronic Trigger level A 1 8 Characteristic Slow blowing Behaviour after en...

Page 17: ......

Page 18: ... others without express authorization is prohibited Offenders will be liable for damages All rights reserved in the event that a patent utility model or design patent is registered Copyright Festo SE Co KG Ruiter Straße 82 73734 Esslingen Germany 49 711 347 0 Phone Internet www festo com ...

Reviews: