background image

Festo   2017-11c  English

5

Example of connection of PELV power unit and potential
equalization

1

PE

2

Potential 
equalization

3

Load voltage can 
be switched off 
separately and 
external fuses

4

Earth connection 
pin 4 (max. 3 A)

PS
MNS

3 1 2 4

1 2 3

4

2

2 A

2 A

Pin assignment of field bus connection (Sub-D-9 socket)

PROFIBUS-
DP

Festo
field
bus

ABB
CS31

SUCOnet
K

Pin 3 (B) 

*)

RxD/TxD-P

S +

Bus-1

T

A

/R

A

Pin 8 (A) 

*)

RxD/TxD-N

S-

Bus-2

T

B

/R

B

Housing 
(Cable clip) 

*)

Screening/shield

*)

In brackets: Connection on Festo Sub-D plug type FBS-SUB-9-GS-9
(TN 18529)

Detailed information can be found in the manual 
P.BE-CP-DI01-.. .

Summary of Contents for CPV..-DI01 series

Page 1: ...Brief description CPV valve termi nal with direct connection type CPV DI01 English 8080242 2017 11c 8080235 Compact Performance...

Page 2: ...tra e 82 73734 Esslingen Germany Internet http www festo com E Mail service_international festo com Reproduction distribution or sale of this document or communication of its contents to others withou...

Page 3: ...re connecting or disconnecting plugs otherwise this could lead to functional damage S Use power supplies which guarantee reliable electri cal isolation of the operating voltage as per IEC DIN EN 60204...

Page 4: ...Ds 4 Switching status display of CP valve coils 5 CP extension connection 6 Switch module removed 1 2 3 4 5 6 Pin assignment of power supply connection M12 connection Pin no 1 24 V DC operating voltag...

Page 5: ...h connection pin 4 max 3 A PS MNS 3 1 2 4 1 2 3 4 2 2 A 2 A Pin assignment of field bus connection Sub D 9 socket PROFIBUS DP Festo field bus ABB CS31 SUCOnet K Pin 3 B RxD TxD P S Bus 1 TA RA Pin 8 A...

Page 6: ...switches field bus pro tocol extension to the CP system field bus address station number diagnostic mode only PROFIBUS or ABB CS31 baud rate only Festo field bus 4 Refit the switch module 5 If the CP...

Page 7: ...t K 4 2 Setting the extension of the CP system 4 element DIL switch Extension to the CP system Setting the DIL switches CPV Direct without extension CPV Direct extended with a CP input module CPV Dire...

Page 8: ...r 8 element DIL switch PROFIBUS DP ABB CS31 SUCOnet K 8 element DIL switch switch elements 1 7 Festo field bus 8 element DIL switch switch elements 1 6 Coded entry Example Station number 38 2 0 1 2 1...

Page 9: ...Device related diagnosis active inactive ABB CS31 Load voltage monitoring active inactive Diagnosis ON Diagnosis OFF 4 5 Set the field bus baud rate only Festo field bus 8 element DIL switch 31 25 kB...

Page 10: ...minal always occupies 16 output addresses A CP valve location occupies two addresses lower value address pilot solenoid 14 higher value address pilot solenoid 12 2 CP valve terminals electric input or...

Page 11: ...IEC DIN EN 60204 1 by means of PELV circuits Protective Extra Low Voltage Protection against explosion as per EU guideline 94 9 EG EN 50021 and EN 50281 1 1 Do not disconnect electrical connec tions...

Page 12: ...2 Load voltage connection Rated value Tolerance Current consumption 24 V DC protection against incorrect polarity fused in ternally switches on again automatically 20 4 26 4 V Sum of all switched on...

Reviews: