Addressing

The CPV Direct must be addressed differently according to
the field bus protocol.  In general the following applies:

1. A CPV valve terminal always occupies 16 output 

addresses.
A CP valve location occupies two addresses:
– lower-value address = pilot solenoid 14
– higher-value address = pilot solenoid 12.

2. CP valve terminals, electric input or output modules on

the extension string each occupy 16 input or output
addresses.

Details and examples of addressing the CP system can be
found in the manual P.BE-CP-DI01-.. .

Summary of Contents for CPV..-DI01 series

Page 1: ...Brief description CPV valve termi nal with direct connection type CPV DI01 English 8080242 2017 11c 8080235 Compact Performance...

Page 2: ...tra e 82 73734 Esslingen Germany Internet http www festo com E Mail service_international festo com Reproduction distribution or sale of this document or communication of its contents to others withou...

Page 3: ...re connecting or disconnecting plugs otherwise this could lead to functional damage S Use power supplies which guarantee reliable electri cal isolation of the operating voltage as per IEC DIN EN 60204...

Page 4: ...Ds 4 Switching status display of CP valve coils 5 CP extension connection 6 Switch module removed 1 2 3 4 5 6 Pin assignment of power supply connection M12 connection Pin no 1 24 V DC operating voltag...

Page 5: ...h connection pin 4 max 3 A PS MNS 3 1 2 4 1 2 3 4 2 2 A 2 A Pin assignment of field bus connection Sub D 9 socket PROFIBUS DP Festo field bus ABB CS31 SUCOnet K Pin 3 B RxD TxD P S Bus 1 TA RA Pin 8 A...

Page 6: ...switches field bus pro tocol extension to the CP system field bus address station number diagnostic mode only PROFIBUS or ABB CS31 baud rate only Festo field bus 4 Refit the switch module 5 If the CP...

Page 7: ...t K 4 2 Setting the extension of the CP system 4 element DIL switch Extension to the CP system Setting the DIL switches CPV Direct without extension CPV Direct extended with a CP input module CPV Dire...

Page 8: ...r 8 element DIL switch PROFIBUS DP ABB CS31 SUCOnet K 8 element DIL switch switch elements 1 7 Festo field bus 8 element DIL switch switch elements 1 6 Coded entry Example Station number 38 2 0 1 2 1...

Page 9: ...Device related diagnosis active inactive ABB CS31 Load voltage monitoring active inactive Diagnosis ON Diagnosis OFF 4 5 Set the field bus baud rate only Festo field bus 8 element DIL switch 31 25 kB...

Page 10: ...minal always occupies 16 output addresses A CP valve location occupies two addresses lower value address pilot solenoid 14 higher value address pilot solenoid 12 2 CP valve terminals electric input or...

Page 11: ...IEC DIN EN 60204 1 by means of PELV circuits Protective Extra Low Voltage Protection against explosion as per EU guideline 94 9 EG EN 50021 and EN 50281 1 1 Do not disconnect electrical connec tions...

Page 12: ...2 Load voltage connection Rated value Tolerance Current consumption 24 V DC protection against incorrect polarity fused in ternally switches on again automatically 20 4 26 4 V Sum of all switched on...

Reviews: