![Festo CMMD-AS series Installation Manual Download Page 72](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_installation-manual_2283097072.webp)
3. Product description
72
Festo P.BE-CMMD-AS-HW-EN 1002NH
I/O timing diagrams
ENABLE
START
STOP
Positioning
record
Drive is moving
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
DOUT0: READY
DOUT1: MC
DOUT2: ACK
DOUT3: ERROR
t1
t1
t1
t1
t1
tx
(1)
t1
= 1.6 ms
tx
= x ms (dependent on positioning)
(1)
Applies for positioning records with end speed = 0
Fig. 3.13 Signal sequence at the start of a sequence