3. Product description
30
Festo P.BE-CMMD-AS-HW-EN 1002NH
Activation of synchronization
Synchronization can be set in various ways.
With the FCT parametrisation software on the "Application Data" page in
the "Operating Modes Settings" tab through selection of the "Synchronisation"
control interface
Via [X1] (digital I/O interface) through selection of mode 3.
Note
With setting of synchronisation via FCT, the controller only reacts
via the synchronisation interface. All other functions of the
"Positioning" operating mode are no longer available.
Note
After the change of configuration with FCT with the "Download"
buttons, load the changed configurations into the motor controller
and save them permanently with the "Save" button.
With a Reset (or switching off and back on) of the motor controller,
the new configuration is activated.
To ensure flexibility of the controller, synchronization should be switched on over the
I/O interface.
Required I/O activation during synchronisation via FCT
-
DIN4
Output stage enable
-
DIN5
Controller enable
-
DIN6
Limit switch 0
-
DIN7
Limit switch 1