Operation and diagnostics
6.1
Operation
Note
The instructions for operation must be created by the system manufacturer. The operat-
or must be instructed in handling the system using the description and must have ac-
cess to it at all times.
6.2
Maintenance and care
6.2.1
Control cabinet fan
Caution
Fire risk from overheating.
Filter mats of the control cabinet fan and the outlet filter:
•
Check regularly for contamination (daily in dusty environments).
•
Replace if necessary.
Procurement of filter mats
Rübsamen & Herr company.
Type AM 435P (216 x 216 mm, filter class G3)
Fig. 6.1
Fig. 6.2
1. Pull the covers of the filter housing off to the
front.
2. Replace the dirty filter mats and dispose of
them in accordance with the instructions
(
7.3 Disposal).
3. Remove the packaging of the new filter mats.
4. Put new filter mats in place
5. Install covers.