background image

CHB-C-N

Checkbox Compact

Festo SE & Co. KG

Ruiter Straße 82

73734 Esslingen

Deutschland

+49 711 347-0

 

www.festo.com

Operating instructions
8167291

2022-01b

[8167293]

Translation of the original instructions

© 2022 all rights reserved to Festo SE & Co. KG

1

Applicable documents

All available documents for the product 

è

  www.festo.com/sp.

Document

Contents

Description of the product

GDCA-CHB-C-N-DE

Description of the function, commissioning,
operation and maintenance of the product

Help for software packages

Software CheckKon P.SW-KON

Software CheckOpti P.SW-OPTI

Operation of the CheckKon software

Operation of the CheckOpti software

Tab. 1: Applicable documents

2

Safety

2.1

Safety instructions

Only use the product in its original condition without unauthorised modifica-
tions. Only the conversions or modifications described in the documentation
supplied with the product are permitted.

Only use the product if it is in perfect technical condition.

Comply with all applicable national and international instructions.

Prior to assembly, installation and maintenance work: Switch off power supply,
ensure that it is off and secure it against being switched back on.

Requirements for product use
For correct and safe use of the product:

Comply with the connection and ambient conditions of the product and all
connected components specified in the technical data. Compliance with the
limit values and load limits permits operation of the product in compliance with
the relevant safety regulations.

Observe the information and warnings in the documentation.

2.2

Intended use

The product is intended for use under normal operating conditions in closed
operating rooms in the industrial sector.
The product is intended exclusively for non-contact checking of the position and
quality of small parts as they pass through.
The orientation and quality-determining features of the test part must be recog-
nisable and distinguishable for the Checkbox.
It must be possible to integrate the Checkbox into the material flow.
2.3

Training of qualified personnel

Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers.
The qualified personnel must be familiar with installation of electrical control
systems.

3

Additional information

Contact the regional Festo contact if you have technical problems

è

  www.festo.com.

Accessories and spare parts 

è

  www.festo.com/catalogue.

4

Product overview

4.1

Structure

4.1.1

Product design

3

1

2

1

Fig. 1: Display and visual elements

1

Prism support

2

Opening for the light beam

3

Display

1

2

3

5

7

4

6

8

9

10

Fig. 2: Connections, display and operating components

1

Reserved for service

2

Buffer/feeder

3

Actuators

4

Encoder

5

24 V DC

6

PLC

7

Ethernet

8

FE

9

Start/Stop illuminated push-
button

10

Status/Teach illuminated push-
button

4.1.2

Display and operating components

Illuminated push-
button

Function

Start/Stop [9]

Starts and stops the Checkbox

Display of the Start (green)/Stop (red) switching function

Set the tolerance

Acknowledging errors

Saving teach data

Status/Teach [10]

Switch between RUN and Teach modes

Select the orientation in the Teach mode

Display of the scan procedure

Open system information
e.g. conveyor speed when operating with an encoder

Tab. 2: Illuminated pushbuttons

4.1.3

Connecting elements

24 VDC connection

Plug

Pin

Signal

1

Do not connect

2

+24 V DC + 20%/–15%

1)

3

GND

4

FE

1) Protect with 4 A fast-acting fuse.

Tab. 3: 24 VDC connection

Connection Actuators

Bushing

Pin

Signals

O/1

Actuator 3

O/2

Actuator 2

3

GND

O/4

Actuator 1

5

Do not connect

Tab. 4: Connection Actuators

Summary of Contents for CHB-C-N

Page 1: ...r The product is intended exclusively for non contact checking of the position and quality of small parts as they pass through The orientation and quality determining features of the test part must be recog nisable and distinguishable for the Checkbox It must be possible to integrate the Checkbox into the material flow 2 3 Training of qualified personnel Work on the product may only be carried out...

Page 2: ...stallation location Please note the following ambient conditions in particular Low vibration installation Stable mechanical mounting Clean ambient air oil free no paint mist no sanding dust Screening of external light influences external heat and extreme magnetic fields e g due to induction furnaces Mounting as cool and vertical as possible This will ensure optimal inspection results and a long se...

Page 3: ...r the GND of the fixed power supply as the GND Do not return any of the output signals at the PLC actuator or buffer plug connector to the GND of any of the other output plugs The outputs are switched off on overload This may also affect the Error and Warning outputs of the PLC interface They are only intended for diagnostics To identify the operating status use the Ready for operation signal that...

Page 4: ...error and if necessary A 23 warning 9 Repair The prism module can be replaced if it is damaged Additional information è Description CHB C N 10 Technical data CHB C N Ambient temperature C 5 50 with 1 A load 5 45 with 3 A load Storage temperature C 20 70 Ambient conditions Dry screened from extreme external light sources cleanest possible ambient air Protection against electric shock PELV Protectiv...