background image

EGC−...−FA−...

Festo  EGC−...−FA−...  0807NH  English

30

12

Characteristic  curves

Force  Fy/Fz  and  support  spacing  L

L

L

EGC−70

EGC−80

EGC−120

EGC−185

EGC−70

EGC−80

EGC−120

EGC−185

Fig.18

Summary of Contents for 558864

Page 1: ...de Bedienungs anleitung en Operating instructions F hrungsachse Guide axis EGC FA 731 344 0807NH...

Page 2: ...personal gem Bedienungs anleitung Warnung Warning Caution Hinweis Please note Umwelt Antipollution Zubeh r Accessories Fitting and commissioning to be carried out by qualified personnel only in accord...

Page 3: ...chl sse 4 2 Funktion und Anwendung 5 3 Transport und Lagerung 5 4 Voraussetzungen f r den Produkteinsatz 5 5 Einbau 6 Einbau mechanisch 6 Einbau schaltungstechnisch 11 6 Inbetriebnahme 12 7 Wartung un...

Page 4: ...en f r Fu befestigung 2 F hrungsschiene 3 BefestigungsgewindeundZentrierungen f r Nutzlast 4 Schlitten 5 Befestigungsfl che f r Profilbefestigung 6 Gewinde f r optionale Schaltfahne 7 Nuten f r N heru...

Page 5: ...einer antriebslosen F hrungsachse EGC FA Sie ist zugelas sen f r die Betriebsart Schlittenbetrieb 3 Transport und Lagerung S Ber cksichtigen Sie das Gewicht des Produkts Je nach Ausf hrung wiegt die...

Page 6: ...wenden Sie das Produkt im Originalzustand ohne jegliche eigenm chtige Ver nderung S Ber cksichtigen Sie die Warnungen und Hinweise in den zugeh rigen Bedie nungsanleitungen S Ber cksichtigen Sie die T...

Page 7: ...ng der F hrungsachse EGC FA in Verbindung mit einer Antriebs achse EGC TB BS KF Hinweis Ung nstige Befestigungsvarianten k nnen die Lebensdauer der EGC stark redu zieren S Verwenden Sie die St tzabst...

Page 8: ...he 5 Nutensteinbefestigung in der Nut 8 Durch Ver kippen gleiten die Nu tensteine an jeder Stelle des Profils in die Nut Bild 4 S Schieben Sie die Querverbindung ber die gesamte Hubstrecke von einer E...

Page 9: ...auf das die max Ein schraubtiefe D eingehalten wird EGC 70 80 120 185 Schraube seitlich oben M5 M5 M6 M6 M8 Max Einschraubtiefe D mm 8 4 9 5 10 15 Zentrierung mm 5 7 9 9 Anziehdrehmoment Nm 5 9 5 9 9...

Page 10: ...h tzen eine EGC mit gebrochenem N herungsschalter Kabel vor ber fahren der Endlage Bei Verwendung von N herungsschaltern als Referenzschalter S Verwenden Sie N herungsschalter entsprechend dem Eingang...

Page 11: ...eckungen in allen ungenutzten Nuten Einbau schaltungstechnisch Hinweis Beim Einsatz in sicherheitsrelevanten Applikationen sind zus tzliche Ma nahmen notwendig In Europa z B die Beachtung der unter de...

Page 12: ...n Sie die Inbetriebnahme anhand der Bedienungsanleitung der An triebsachse z B EGC BS TB KF 7 Wartung und Pflege Zur Reinigung und Pflege S Reinigen Sie die F hrungsschiene bei Bedarf mit einem weiche...

Page 13: ...ungsvergleichszahl Fver mit Hilfe der Formel f r kombinierte Belastungen Kapitel 11 Technische Daten und entnehmen Sie das Schmier intervall Sint aus Bild 13 2 Fetten Sie die W lzf hrung beidseitig an...

Page 14: ...gliche Ursache Abhilfe Quietsch ger usche Vibra tionen oder Achse l uft rau Verspannungen EGC verspannungsfrei einbauen Ebenheit der Auflagefl che Kapitel 5 Ein bau mechanisch l uft rau EGC exakt para...

Page 15: ...den Schlitten Fymax Fzmax N 1850 3050 6890 15200 Zul Momente auf den Schlitten Mxmax Mymax Mzmax EGC GK GP Mymax Mzmax EGC GV GQ Nm 16 51 132 36 97 228 144 380 680 529 1157 1820 Bedingungf rkombiniert...

Page 16: ...EGC FA Festo EGC FA 0807NH Deutsch 16 12 Kennlinien Kraft Fy Fz und St tzabstand L L L EGC 70 EGC 80 EGC 120 EGC 185 EGC 70 EGC 80 EGC 120 EGC 185 Bild 18...

Page 17: ...and application 19 3 Transportation and storage 19 4 Requirements for use of the product 19 5 Installation 20 Mechanical installation 20 Fitting electric components 25 6 Commissioning 26 7 Care and ma...

Page 18: ...les to fix the feet 2 Guide rail 3 Mounting thread and centring holes for payload 4 Slide 5 Mounting surfaces for profile mounting attachment 6 Thread for optional switch lug 7 Slots for proximity swi...

Page 19: ...s It is approved for slide operating mode 3 Transportation and storage S Take into account the weight of the product Depending on the version the EGC can weigh up to 340 kg S Ensure that the storage c...

Page 20: ...original state without any unauthorised modifications S Note the warnings and instructions on the product and in the relevant operating instructions S Take the tolerance of the tightening torques into...

Page 21: ...rry out an individual functional test If the EGC FA guide axis is used in conjunction with a drive axis type EGC TB BS KF Note Unsuitable mounting techniques can reduce the service life of the EGC con...

Page 22: ...Slot nut mounting in slot 8 When tilted the slot nuts slide into the groove at each point on the profile Fig 4 S Push the lateral connection over the complete stroke path from one end position to the...

Page 23: ...that the maximum screw in depth D is adhered to EGC 70 80 120 185 Screw side top M5 M5 M6 M6 M8 Max screw in depth D mm 8 4 9 5 10 15 Centringhole mm 5 7 9 9 Tighteningtorque Nm 5 9 5 9 9 9 9 9 24 Fig...

Page 24: ...sed function These will protect a EGC with a fractured proximity switch cable against over running the end position If proximity sensors are used as reference switches S Use the proximity switches in...

Page 25: ...lot covers in all unused grooves Fitting electric components Note If used in safety relevant applications additional measures are necessary In Europe e g the standards listed in the EC machine directi...

Page 26: ...ion the unit following the operating instructions for the drive axis e g EGC BS TB KF 7 Care and maintenance On cleaning and care S If required clean the guide axis with a soft cloth Use any non abras...

Page 27: ...GQ 1 Calculate the guide comparison number Fver with the aid of the formula for com bined loadings chapter 11 Technical data and select the lubricating interval Sint from Fig 13 2 Grease the bearing g...

Page 28: ...queakingnoises vibrations or the axis is not running smoothly Distortions Install the EGC without stress evenness of bearing surface chapter 5 Fitting mechanical components smoothly Align the EGC so t...

Page 29: ...on the slide Fymax Fzmax N 1850 3050 6890 15200 Permitted torque on the slide Mxmax Mymax Mzmax EGC GK GP Mymax Mzmax EGC GV GQ Nm 16 51 132 36 97 228 144 380 680 529 1157 1820 Condition for combined...

Page 30: ...EGC FA Festo EGC FA 0807NH English 30 12 Characteristic curves Force Fy Fz and support spacing L L L EGC 70 EGC 80 EGC 120 EGC 185 EGC 70 EGC 80 EGC 120 EGC 185 Fig 18...