DNCM−...−POT
Festo DNCM−...−POT 0608a English
23
Pne
uma
ti
c
c
o
m
ponent
s
When using the DNCM−...−POT with electronic closed−loop control:
Ple
as
e note
Special fitting conditions apply to the electronically closed−loop control of the
DNCM−...−POT:
S
Observe the instructions in the manuals for positioning controller type SPC−...
(Soft Stop).
S
Remove the adhesive labels on the com
pressed air ports
aG
.
When using the DNCM−...−POT as a measuring
cylinder:
S
Use a one−way flow control valve type
GRLZ−..., type GRLA−... directly in the
relevant compressed air port.
If there is a drop in pressure on a system
where the cylinder is mounted in a vertical
position, non−return valves ensure that
the mass remains in the position reached
and doess not slide down.
Using the DNCM−...−POT with electronic
closed−loop control:
S
Use proportional directional control valve
type MPYE−5−... .
Only in this way will the piston remain in
the held position clamped between the
end positions.
In conjunction with such a circuit, the
control electronics compensate for the
difference in pressure due to the different
piston surfaces automatically.
S
Connect the DNCM−...−POT to the com
pressed air ports
1
.
Fig.11
Fig.12