Fervi C033/150 Operation And Maintenance Manual Download Page 3

MEASURING

INSTRUMENTS

Page 3 of 5

1 WARNINGS

1. Before using the caliper clean the surface of the protective sticker using a clean, dry

cloth. To remove stubborn dirt, use a cloth lightly dampened with ethyl alcohol.

2. Conditions of use

Temperature:

5 – 40°C

Relative humidity:

less than 80%

3. Prevent the protective sticker from coming into contact with liquids containing water

that could damage the circuit board.

4. Do not allow any part of the digital caliper to come into contact with electric current

(e.g. impact with an electric pen) to prevent damage to the integrated circuits.

5. Remove the battery from its compartment when the caliper is not in use for a long

period of time.

2 DESCRIPTION OF THE INSTRUMENT

Figure 1 - Overview

1

Scale measurement face

8

Protective sticker

2

Internal measurement faces

9

Depth measurement bar

3

LCD screen

10

External measurement faces

4

Locking screw

11

ON/OFF button

5

1.5V button battery

12

Reset button

6

Battery cover

13

Measurement unit change button

7

Slider

fervi.com

Summary of Contents for C033/150

Page 1: ...OPERATION AND MAINTENANCE MANUAL Digital caliper Art C033 150 C033 200 C033 300 TRANSLATION OF THE ORIGINAL INSTRUCTIONS f e r v i c o m ...

Page 2: ...ssess all the necessary information and instruction and should be given adequate training in relation to safety regarding a Conditions of use for the equipment b Foreseeable abnormal situations pursuant to Article 73 of Legislative Decree 81 08 We guarantee the instrument complies with the specifications and technical instructions described in the Manual on the date of its issuance shown in this p...

Page 3: ...d 4 Do not allow any part of the digital caliper to come into contact with electric current e g impact with an electric pen to prevent damage to the integrated circuits 5 Remove the battery from its compartment when the caliper is not in use for a long period of time 2 DESCRIPTION OF THE INSTRUMENT Figure 1 Overview 1 Scale measurement face 8 Protective sticker 2 Internal measurement faces 9 Depth...

Page 4: ... of inactivity 4 OPERATING INSTRUCTIONS Dry the protective sticker area and clean the measuring surfaces Loosen the locking screw and move the slider to make sure that the LCD screen and the buttons are working properly Turn on the caliper by pressing the ON OFF button Press the measurement unit change button if necessary to select the desired unit of measurement Bring the two measuring faces gent...

Page 5: ...h identical specifications The positive pole of the battery should be facing outward After replacing the battery it will be necessary to reset the instrument 6 TROUBLESHOOTING Problem Possible causes Solutions Flashing digits Low voltage Replace the battery Display off Low voltage Poor contact of the battery Replace the battery Adjust the position of the battery and clean the housing Fixed digits ...