PREFACE

Please ensure you have read this manual before any
operation

TRANSLATION OF THE ORIGINAL INSTRUCTIONS

It is compulsory to read this instruction manual before starting operation. The guarantee of

smooth operation and full performance of the instrument is highly dependent on the
application of all the instructions contained in this manual.

Operator Qualifications

The workers in charge of using this instrument must possess all the necessary
information and instruction and should be given adequate training in relation to safety

regarding:
a)

Conditions of use for the equipment;

b)

Foreseeable abnormal situations, pursuant to Article 73 of Legislative Decree

81/08.

We guarantee the instrument complies with the specifications and technical
instructions described in the Manual on the date of its issuance (shown in this page).
On the other hand, the instrument may also be subject to important technical changes
in the future, without the manual being updated.
Therefore, contact FERVI for information about modifications that may have been
implemented.

REV. 1

October 2013

fervi.com

Summary of Contents for C033/150

Page 1: ...OPERATION AND MAINTENANCE MANUAL Digital caliper Art C033 150 C033 200 C033 300 TRANSLATION OF THE ORIGINAL INSTRUCTIONS f e r v i c o m ...

Page 2: ...ssess all the necessary information and instruction and should be given adequate training in relation to safety regarding a Conditions of use for the equipment b Foreseeable abnormal situations pursuant to Article 73 of Legislative Decree 81 08 We guarantee the instrument complies with the specifications and technical instructions described in the Manual on the date of its issuance shown in this p...

Page 3: ...d 4 Do not allow any part of the digital caliper to come into contact with electric current e g impact with an electric pen to prevent damage to the integrated circuits 5 Remove the battery from its compartment when the caliper is not in use for a long period of time 2 DESCRIPTION OF THE INSTRUMENT Figure 1 Overview 1 Scale measurement face 8 Protective sticker 2 Internal measurement faces 9 Depth...

Page 4: ... of inactivity 4 OPERATING INSTRUCTIONS Dry the protective sticker area and clean the measuring surfaces Loosen the locking screw and move the slider to make sure that the LCD screen and the buttons are working properly Turn on the caliper by pressing the ON OFF button Press the measurement unit change button if necessary to select the desired unit of measurement Bring the two measuring faces gent...

Page 5: ...h identical specifications The positive pole of the battery should be facing outward After replacing the battery it will be necessary to reset the instrument 6 TROUBLESHOOTING Problem Possible causes Solutions Flashing digits Low voltage Replace the battery Display off Low voltage Poor contact of the battery Replace the battery Adjust the position of the battery and clean the housing Fixed digits ...