SUN G50 - G70
30
Cod. 35445644 - 08/2007 (Rev. 00)
GB
Fitting nozzles
After determining the right nozzles to use, go ahead and fit them as follows:
1
Unscrew the screws
“A”
2
Take off the casing
“B”
3
Using a wrench, unscrew the couplings
“C”
by half a turn
4
Take the copper tubes
“D”
out of the couplings
5
Slightly unscrew the screws
“E”
6
Turn and take out the head/nozzle-holder assembly
“F”
7
Unscrew the two screws
“G”
8
Using a wrench, unscrew the nozzles
“I”
fig. 5
C
F
G
I
B
A
D
E
F
Nozzle
2nd stage
Nozzle
1st stage