Ferroli RMP series Technical Manual Download Page 21

21

Electrical data

Frame

1

2

Model

19 .1

22 .1

26 .1

30 .1

35 .1

40 .1

U.M.

Power supply

400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50

V-ph-Hz

F.L.A.

Maximum total current input

28,9

30,9

33,0

28,0

32,0

36,1

A

F.L.I.

Maximum total power input

13,0

14,3

15,6

16,8

19,4

22,0

kW

M.I.C.

Maximum total start current

108

124

131

131

146

180

A

Maximum total start current

with soft starter (option)

65

74

78

75

84

104

A

Unit

Power supply

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

V-ph-Hz

F.L.A.

Maximum total current input

3,6

3,6

3,6

3,6

5,1

5,1

A

F.L.I.

Maximum total power input

0,7

0,7

0,7

0,7

1,0

1,0

kW

Standard pump (option)

Power supply

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

V-ph-Hz

F.L.A.

Maximum total current input

6,1

6,1

6,1

6,1

8,2

8,2

A

F.L.I.

Maximum total power input

1,2

1,2

1,2

1,2

1,6

1,6

kW

High head pump (option)

Power supply

400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50

V-ph-Hz

F.L.A.

Maximum total current input

3,6

3,6

3,6

3,6

5,1

5,1

A

F.L.I.

Maximum total power input

0,7

0,7

0,7

0,7

1,0

1,0

kW

Modulating pump (option)

Power supply

400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50

V-ph-Hz

F.L.A.

Maximum total current input

9,5

9,5

9,5

9,5

9,5

9,5

A

F.L.I.

Maximum total power input

6,6

6,6

6,6

6,6

6,6

6,6

kW

Integrative electrical heaters standard in the tank (option)

TECHNICAL DATA AND PERFORMANCES

Noise levels

Model

Sound power levels [dB] 

by octave bands [Hz]

Sound power

level

Sound pressure level

at 1 metre

at 5 metres at 10 metres

63

125

250

500 1000 2000 4000 8000

[dB]

[dB(A)]

[dB(A)]

[dB(A)]

[dB(A)]

Base setting up (AB)

19 .1

85,1

79,4

74,3

73,2

71,3

68,4

62,6

57,6

87

76

60

50

45

22 .1

85,3

79,6

74,5

73,4

71,5

68,6

62,8

57,8

87

76

60

50

45

26 .1

86,3

80,6

75,5

74,4

72,5

69,6

63,8

58,8

88

77

61

51

46

30 .1

89,3

83,6

78,5

77,4

75,5

72,6

66,8

61,8

91

80

64

54

49

35 .1

89,8

84,1

79,0

77,9

76,0

73,1

67,3

62,3

92

81

65

55

49

40 .1

90,3

84,6

79,5

78,4

76,5

73,6

67,8

62,8

92

81

65

55

50

Low noise setting up (AS)

19 .1

83,1

77,4

72,3

71,2

69,3

66,4

60,6

55,6

85

74

58

48

43

22 .1

83,3

77,6

72,5

71,4

69,5

66,6

60,8

55,8

85

74

58

48

43

26 .1

84,3

78,6

73,5

72,4

70,5

67,6

61,8

56,8

86

75

59

49

44

30 .1

87,3

81,6

76,5

75,4

73,5

70,6

64,8

59,8

89

78

62

52

47

35 .1

87,8

82,1

77,0

75,9

74,0

71,1

65,3

60,3

90

79

63

53

47

40 .1

88,3

82,6

77,5

76,4

74,5

71,6

65,8

60,8

90

79

63

53

48

Reference conditions

Performances referred to units operating in cooling mode at nominal conditions A35W7.

Unit placed in free field on reflecting surface (directional factor equal to 2).

Unit ducted on the sunction and on the flow side for 2 meters.

The sound power level is measured according to ISO 3744 standard.

The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

Summary of Contents for RMP series

Page 1: ...RMP AIR WATER CHILLERS AND HEAT PUMPS FOR INDOOR INSTALLATION TECHNICAL MANUAL R E F R I G E R A N T G A S E C O FRIEND L Y...

Page 2: ...s all the responsabilities regarding inaccuracies contained in this manual if due to printing or typing mi stakes The manufacturer reserves the right to apply changes and improvements to the products...

Page 3: ...ng up VB Standard plants 11 NOMINAL performances Base setting up VB Radiant plants 12 NOMINAL performances Low noise setting up AS Standard plants 13 NOMINAL performances Low noise setting up AS Radia...

Page 4: ...4...

Page 5: ...emissions in such operating conditions The low noise acoustic setting up AS is obtained starting from the base setting up AB reducing the rotational speed of the fans and mounting sound jackets on th...

Page 6: ...switches in order to assure the compressor to operate inside the permitted limits 4 way reverse cycle valve 6 to allow operating mode change reversing the refrigerant flow only heat pump models liqui...

Page 7: ...mpressor and pump operating hours recording serial communication through Modbus protocol remote stand by remote cooling heating general alarm digital output Versions Each model can be supplied in thre...

Page 8: ...tee a more stable flow temperature Tank and modulating pump Allows the circulation of the water on the plant side with the possibility to set the rotational speed of the pump in order to get the reque...

Page 9: ...he operating conditions of the unit through Modbus communication protocol The RS485 serial line ensures the signal quality up to distances of about 1200 meters that can be extended by means of proper...

Page 10: ...nd embedded inverter plug fan with EC motor and embedded inverter plug fan with EC motor and embedded inverter plug fan with EC motor and embedded inverter Quantity 1 1 1 1 1 1 n Diameter 630 630 630...

Page 11: ...Pressure drops plant side 19 23 19 27 23 28 kPa IR Cooling A35W7 source air in 35 C d b plant water in 12 C out 7 C Cooling capacity 20 0 22 2 25 9 31 0 35 8 40 4 kW EER 2 97 3 00 2 99 2 92 2 96 2 95...

Page 12: ...7 33 2 38 4 43 3 kW Power input 5 48 6 03 7 03 8 71 9 91 11 3 kW COP 3 91 3 95 3 94 3 81 3 87 3 83 Water flow rate plant side 3651 4063 4731 5657 6549 7371 l h Pressure drops plant side 29 35 29 40 3...

Page 13: ...ure drops plant side 17 21 17 24 21 26 kPa Frame 1 2 Model 19 1 22 1 26 1 30 1 35 1 40 1 U M Power supply 400 3N 50 400 3N 50 400 3N 50 400 3N 50 400 3N 50 400 3N 50 V ph Hz IR Cooling A35W7 source ai...

Page 14: ...31 6 36 5 41 2 kW Power input 5 24 5 77 6 73 8 34 9 49 10 9 kW COP 3 87 3 92 3 91 3 79 3 85 3 78 Water flow rate plant side 3463 3857 4491 5383 6223 7011 l h Pressure drops plant side 26 32 26 37 31 3...

Page 15: ...e graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions The reference nominal condition is...

Page 16: ...allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions The reference nominal condition is A7W35 sou...

Page 17: ...to units operating with water at the temperature of 10 C density 1000 kg m3 Flow rate l h Pressure drops kPa 0 40 80 120 160 200 240 280 320 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Available s...

Page 18: ...0 3000 4000 5000 6000 7000 8000 9000 Available static head unit with option Storing and pumping module Modulating pump or Tank and modulating pump The graphs are referred to units operating with water...

Page 19: ...tion must guarantee that the medium air velocity does not exceed 2 5 m s in order to avoid noise problems and to keep the pressure drops lower as possible Source side aeraulic performances Available s...

Page 20: ...0 45 50 55 60 65 25 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 HEATING Inlet air temperature d b C Outlet temperature plant side C The graphs reported below show the operating area inside which the cor...

Page 21: ...ctrical heaters standard in the tank option TECHNICAL DATA AND PERFORMANCES Noise levels Model Sound power levels dB by octave bands Hz Sound power level Sound pressure level at 1 metre at 5 metres at...

Page 22: ...pump 12 12 12 14 16 16 kg Tank and standard pump 31 31 31 31 33 33 kg Tank and high head pump 34 34 34 34 35 35 kg Tank and modulating pump 34 34 34 36 38 38 kg Integrative electrical heaters Standar...

Page 23: ...1453 24 53 576 131 614 215 G F 73 368 74 F 73 368 24 1 2 1 2 B C A Plant return Plant flow Frame 1 2 Model 19 1 22 1 26 1 30 1 35 1 40 1 1 1 1 4 F 1 1 4 F 1 1 4 F 1 1 4 F 1 1 4 F 1 1 4 F 2 1 1 4 M 1 1...

Page 24: ...Cod 3QE29590...

Reviews: