BOILER CONTROLLER - SERVICE MENU
10. BOILER CONTROLLER - SERVICE MENU
ALL ADJUSTMENTS DESCRIBED IN THIS SECTION CAN ONLY BE CARRIED OUT BY QUALIFIED PERSON-
NEL.
10.1 Adjustments
Gas conversion
The unit can work with 2ndor 3rd family gases, and this is clearly indicated on the packaging and on the data plate of the unit. If the unit has to be used with a gas
other than the factory-set one, proceed as follows:
Disconnect the power supply and turn off the gas.
Remove the front panel (see “15.7 Extraordinary maintenance and replacement of heat pump components” on page 91).
Apply the label, contained in the conversion kit, near the data plate.
Refit the front panel and turn on the power to the boiler.
Modify the parameter for the type of gas:
Put the boiler in standby mode and press the Reset button (detail 6 - fig. 151) for 10 seconds.
The display shows 100 and the text “co” flashing; press the “H” button (detail 4 - fig. 151) to set and view 120.
Then press the “DHW +” button (detail 2 - fig. 151) to set 123.
Press the Reset button once (detail 6 - fig. 151).
The display shows tS flashing; press the “H” button once (detail 4 - fig. 151).
The display shows Sc flashing; press the Reset button once (detail 6 - fig. 151).
The display shows Sc alternating with 01 flashing;
press the “H” button (detail 4 - fig. 151).
The display shows Sc alternating with 02 flashing;
Press the Reset button (detail 6 - fig. 151) for 10 seconds; the boiler will return to standby.
The fan will be activated for about 20 seconds.
Turn on the gas.
MAKE SURE THE FRONT CASING IS CLOSED AND THE INTAKE/FUME EXHAUST DUCTS ARE COMPLETELY ASSEMBLED
Put the boiler in heating or DHW mode for at least 2 minutes. During this period the boiler performs a calibration and the flame symbol flashes on the display. The
end of calibration is indicated by the flame symbol steady on the display.
Check the combustion values (see following par.).
Table. 7 - THROTTLE position and parameter setting
Gas family
Gas type
Throttle position
Parameter setting
2
nd
G20 - G25 - G27 - G25.1 - G25.3
1
nA
2
nd
G230
1
LP
3
rd
G30 - G31
2
LP
fig. 164 -
fig. 165 -
Summary of Contents for OMNIA HYBRID C
Page 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Page 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Page 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Page 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Page 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Page 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Page 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Page 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Page 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Page 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...