42
SETUP OF THE SYSTEM
When the cursor is on OPERATE PREHEATING FOR FLOOR, Use
◄
►
to scroll to
YES and press OK. The page will be displayed as follows:
During preheating for
fl
oor, all the buttons except OK are invalid. If you want to turn off
the preheating for
fl
oor, please press OK. The following page will be displayed:
Use
◄
►
to scroll the cursor to YES and press OK, the preheating for
fl
oor will turn off.
Before
fl
oor heating, if large a amount of water remains on the
fl
oor, the
fl
oor may be
warped or even rupture during
fl
oor heating operation, in order to protect the
fl
oor,
fl
oor
drying is necessary, during which the temperature of the
fl
oor should be increased
gradually.
If FLOOR DRYING UP is selected, after press OK ,the page will displayed as follows:
When the cursor is on OPERATE FLOOR DRYING? Use
◄
►
to scroll to YES and
press OK. The page will be displayed as follows:
During
fl
oor drying, all the buttons except OK are invalid. When the heat pump mal-
functions, the
fl
oor drying mode will turn off when the backup heater and additional
heating source is unavailable. If you want to turn off
fl
oor drying up, please press OK.
The following page will be displayed:
Use
◄
►
to scroll the cursor to YES and press OK. Floor drying will turn off.
When the cursor is on WARM UP TIME (t_DRYUP), KEEP
TIME (t_HIGHPEAK), TEMP. DOWN TIME (t_DRYD), PEAK
TEMP. (T_DRYPEAK), START TIME or START DATA, Use
◄
►
and
▼
▲
to scroll and adjust the parameter.
t_DRYUP is the day for warming up.
t_HIGHPEAK is the last day of high temperature.
t_DRYD is the day of dropping temperature
T_DRYPEAK is the target peak temperature of water
fl
ow
during
fl
oor drying up.
The target outlet water temperature during
fl
oor drying up
described
in the picture below:
12.2 PREHEATING FOR FLOOR
Preheat for floor is
running for 25 minutes.
Water flow temperature is 20
°C.
CONFIRM
OK
12.2 PREHEATING FOR FLOOR
Do you want to turn of the
preheating for floor function?
SCROLL
CONFIRM
OK
NO
YES
12.3 FLOOR DRYING UP
WARM UP TIME(t_DRYUP)
KEEP TIME(t HIGHPEAK)
PEAK TEMP. (T_DRYPEAK)
START TIME
START DATE
8 days
5 days
45°C
15:00
01-05-2015
SCROLL
1/2
t_DRYUP
t_DRYPEAK
T1S
t
t_DRYD
T_DRYPEAK
12.3 FLOOR DRYING UP
The unit will operate floor
drying on 09:00 16-12-2015.
CONFIRM
OK
Use
▼
,
▲
,
◄
,
►
to scroll and use OK to select YES or NON to enable or disable
the auto restart function. If the auto restart function is enabled, when power returns
after a power supply failure, the AUTO RESTART function reapplies the user interface
settings at the time of the power supply failure. If this function is disabled, when power
returns after a power supply failure, the unit won’t auto restart.
Auto restart
The AUTO RESTART function is used to select whether the unit reapplies the user interface settings at the time when power
returns after a power supply.
Go to MENU> FOR SERVICEMAN> AUTO RESTART
13 AUTO RESTART
DHW MODE
COOL/HEAT MODE
SCROLL
YES
YES
NO
NO
Summary of Contents for OMNIA H 04E
Page 26: ...26 FOR SEVICEMAN menu SETUP OF THE SYSTEM...
Page 27: ...27 SETUP OF THE SYSTEM...
Page 28: ...28 SETUP OF THE SYSTEM...
Page 29: ...29 SETUP OF THE SYSTEM...
Page 46: ...46 The overview pages available user CONTROL SYSTEM...
Page 47: ...47 CONTROL SYSTEM...