26
CONTROL SYSTEM
Control system configuration
The control system can be configured in different ways in order
to adapt itself to the user needs and to the kind of plant managed
by the heat pump.
The simpler configuration consists of unit controller (A) and ou-
tdoor air temperature sensor (B). Such components are always
supplied with the unit and allow to realize a climatic control based
only on the outdoor air temperature.
The user interface, necessary to modify set points and operating
parameters and to visualize alarm messages, is the remote con-
trol (C) to be installed inside the building.
The communication between the devices of the control system can be carried out through wired or wireless connections. To realize a
wireless network are available, as accessories : wireless transmitter (F) to be connected to the heat pump controller, wireless adaptor
for outdoor temperature sensor (G) , wireless remote control (H) and wireless repeater (I) to be used to amplify the signal when the
distance between the devices is large.
The remote control can be used, besides as user interface, also as room unit for the management of a zone both in heating and in
cooling. The temperature sensor contained inside the remote control allows to detect the room temperature and to realize a climatic
control based on the outdoor air temperature and on the room temperature.
If the heat pump controller manages a further heating zone, in order to realize a climatic control based on the outdoor air temperature
and on the room temperature, it is necessary to add a remote thermostat (D) dedicated to that zone.
Q
B
q
k
e
b
N
L
BSB
X60
LPB
Q
B
q
k
e
b
N
L
BSB
X60
LPB
Q
B
q
k
e
b
N
L
BSB
X60
LPB
User
interface
Outdoor
air sensor
Heat pump
controller
Outdoor
air sensor
Outdoor
air sensor
Heat pump
controller
Heat pump
controller
Remote
control
zone 1
Remote
thermostat
zone 2
Remote
control
zone 1
Remote
control
zone 2