Connection with separate pipes
fig. 12 - Examples of connection with separate pipes (
= Air /
= Fumes)
For the connection of separate pipes, fit the following starting accessory on the appliance:
fig. 13 - Starting accessories for separate ducts
Before carrying out installation, check that the maximum permissible length is not exceeded, by means of a simple cal-
culation:
1. Completely define the layout of the system of split flues, including accessories and outlet terminals.
2. Consult the table 3 and identify the losses in m
eq
(equivalent metres) of every component, according to the instal-
lation position.
3. Check that the sum total of losses is less than or equal to the maximum permissible length in table 2.
Table. 2 - Maximum length of separate pipes
Separate pipes
Maximum permissible length
55 m