1. GENERAL INSTRUCTIONS

Carefully read the instructions contained in this instruction booklet.

After boiler installation, inform the user regarding its operation and give him this manual, which is
an integral and essential part of the product and must be kept with care for future reference.

Installation and maintenance must be carried out by professionally qualified personnel, according
to current regulations and the manufacturer's instructions. Do not carry out any operation on the
sealed control parts.

Incorrect installation or inadequate maintenance can result in damage or injury. The Manufacturer
declines any liability for damage due to errors in installation and use or failure to follow the instruc-
tions.

Before carrying out any cleaning or maintenance operation, disconnect the unit from the power
supply using the system switch and/or the special cut-off devices.

In case of a fault and/or poor operation, deactivate the unit and do not attempt to repair it or directly
intervene. Contact professionally qualified personnel. Repair/replacement of the products must
only be carried out by professionally qualified using original spare parts. Failure to comply with the
above could affect the safety of the unit.

This unit must only be used for its intended purpose. Any other use is considered improper and
therefore dangerous.

The packing materials are potentially hazardous and must not be left within the reach of children.

The images given in this manual are a simplified representation of the product. In this represen-
tation there may be slight and insignificant differences with respect to the product supplied.

2. OPERATING INSTRUCTIONS

2.1 Introduction

Dear Customer,

DOMIcondens F 28

 is a high-efficiency sealed chamber

 condensing

 heat generator for

heating and hot water production running on natural gas or LPG, and equipped with a
microprocessor control system.

2.2 Control panel

fig. 1  - Control panel

Key

1 =

Domestic hot water temperature setting

3 =

Heating system temperature setting

5 =

Display

6 =

Summer/Winter mode selection - Reset button

7 =

Unit On/Off - Eco/Comfort mode selection button

9 =

DHW mode

10 =

Summer mode

11 =

Temperature or faults

12 =

Eco (Economy) mode

13 =

Heating

15 =

Burner On and actual power

16 =

Clock prearrangement

Indication during operation

Heating

A heating demand (generated by the Room Thermostat or Remote Timer Control) is in-
dicated by flashing of the hot air above the radiator on the display. 

Domestic hot water (DHW)

A DHW demand (generated by drawing domestic hot water) is indicated by flashing of
the hot water under the tap on the display. 

2.3 Lighting and turning off

Connection to the power supply

During the first 5 seconds the display shows the card software version.

Open the gas cock ahead of the boiler.

The boiler is now ready to operate automatically whenever hot water is drawn or in
case of a room thermostat demand.

Boiler lighting and shutdown

Press the 

on/off

 button (detail 7 - fig. 1) for 5 seconds.

fig. 2 - Turning the boiler off

When the boiler is turned off, the PCB is still powered. Domestic hot water and heating
are disabled. The antifreeze system remains activated. To relight the boiler, press the

on/off

 button  (detail 7 fig. 1) again for 5 seconds.

fig. 3

The boiler will be immediately ready to operate whenever domestic hot water is drawn
or in case of a room thermostat demand.

B

The antifreeze system does not work when the power and/or gas to the unit are
turned off. To avoid damage caused by freezing during long idle periods in win-
ter, it is advisable to drain all water from the boiler, DHW circuit and system; or
drain just the DHW circuit and add a suitable antifreeze to the heating system,
complying with that prescribed in sec. 3.3.

2.4 Adjustments

Summer/Winter Switchover

Press the 

summer/winter

 button (detail 6 - fig. 1) for 2 seconds.

The display activates the Summer symbol (detail 10 - fig. 1): the boiler will only deliver
domestic hot water. The antifreeze system remains activated.

To deactivate the Summer mode, press the 

summer/winter

 button (detail 6 - fig. 1)

again for 2 seconds.

Heating temperature setting

Use the heating buttons (detail 3 - fig. 1) to adjust the temperature from a min. of 30°C
to a max. of 85°C; it is advisable not to operate the boiler below 45°C. 

fig. 4

Hot water temperature adjustment

Use the DHW buttons (detail 1 - fig. 1) to adjust the temperature from a min. of 40°C to
a max. of 55°C.

fig. 5

Room temperature adjustment (with optional room thermostat)

Using the room thermostat, set the temperature required in the rooms. If the room ther-
mostat is not installed, the boiler will keep the system at the set system delivery setpoint
temperature.

Room temperature adjustment (with optional remote timer control)

Using the remote timer control, set the required temperature in the rooms. The boiler will
adjust the system water according to the required room temperature. For operation with
remote timer control, please refer to the relevant instruction manual.

ECO/COMFORT selection

The unit has a function that ensures a high domestic hot water delivery speed and max-
imum comfort for the user. When the device is activated (COMFORT mode), the water
contained in the boiler is kept hot, therefore ensuring immediate availability of hot water
on opening the tap, without waiting times.

The device can be deactivated by the user (ECO mode) by pressing the 

eco/comfort

button (detail 7 - fig. 1) with the boiler in standby mode. In ECO mode the display acti-
vates the ECO symbol (detail 12 - fig. 1). To activate COMFORT mode, press the 

eco/

comfort

 button (detail 7 - fig. 1) again.

16

eco

comfort

reset

9

15

13

12

11

10

1

3

6

7

5

Summary of Contents for DOMIcondens F 28

Page 1: ...Supplied By www heating spares co Tel 0161 620 6677 3540S920 cod 3540S920 05 2009 Rev 00 DOMIcondens F 28 700 400 196 85 115 200 330 INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Page 2: ...r supply During the first 5 seconds the display shows the card software version Open the gas cock ahead of the boiler The boiler is now ready to operate automatically whenever hot water is drawn or in case of a room thermostat demand Boiler lighting and shutdown Press the on off button detail 7 fig 1 for 5 seconds fig 2 Turning the boiler off When the boiler is turned off the PCB is still powered ...

Page 3: ...ding those with sealed chamber The unit is suitable for operation in a partially protected place in conformity with EN 297 A6 with minimum temperature 5 C If equipped with the special antifreeze kit it can be used with minimum temperatures to 15 C The boiler must be installed is a protected place e g under the slope of a roof inside a balcony or in a sheltered recess The place of installation must...

Page 4: ...t product in the right concentration accord ing to the producer s instructions 3 4 Gas connection The gas must be connected to the relevant connection see fig 7 in conformity with cur rent standards with a rigid metal pipe or with a continuous surface flexible s steel tube installing a gas cock between the system and boiler Make sure all the gas connections are tight 3 5 Electrical connections B T...

Page 5: ...etely establish the layout of the system of split flues including accessories and outlet terminals 2 Consult the table 4 and identify the losses in meq equivalent metres of every com ponent according to the installation position 3 Check that the sum total of losses is less than or equal to the maximum permissible length in table 3 Table 3 Baffles for separate ducts Table 4 Accessories 3 7 Condensa...

Page 6: ...djust the maximum pressure by turning the screw G clockwise to increase the pressure and anticlockwise to decrease it Disconnect one of the two fastons C from the modureg F on the gas valve Adjust the minimum pressure by turning the screw E clockwise to increase the pressure and anticlockwise to decrease it Turn the burner on and off checking that the minimum pressure remains stable Reconnect the ...

Page 7: ...aults marked with the letter F cause temporary shutdowns that are automatically reset as soon as the value returns within the boiler s normal working range Table of faults Table 5 Fault list Fault code Fault Possible cause Cure A01 No burner ignition Excessive condensate level Empty clean the trap No gas Check the regular gas flow to the boiler and that the air has been eliminated from the pipes I...

Page 8: ...500 2 000 Q l h H m H 2 O A 3 2 1 Data Unit DOMIcondens F 28 Max heating capacity kW 27 2 Q Min heating capacity kW 10 0 Q Max Heat Output in heating 80 60 C kW 26 2 P Min Heat Output in heating 80 60 C kW 9 2 P Max Heat Output in heating 50 30 C kW 28 2 Min Heat Output in heating 50 30 C kW 9 6 Max heating capacity in hot water production kW 27 2 Min heating capacity in hot water production kW 10...

Page 9: ...ndens F 28 9 EN cod 3540S920 05 2009 Rev 00 fig 21 Wiring diagram X4 1 2 3 4 5 6 7 43 278 11 10 9 8 7 6 5 4 3 2 1 X6 114 42 47 38 L N X1 X5 1 X3 3 2 X7 32 4 3 2 1 44 DBM02 1B 81 230V 50 Hz T T T 16 ON DAY 22 0004 REMOVE TO CONNECT THE CLOCK 139 193 126 1 2 72 ...

Page 10: ...SCALE REDUCER HAS BEEN FITTED FOR THE DOMESTIC HOT WATER MODE MEASURE RECORD GAS RATE ft3 hr MAXIMUM BURNER OPERATING PRESSURE IF APPLICABLE mbar COLD WATER INLET TEMPERATURE C HOT WATER OUTLET TEMPERATURE C WATER FLOW RATE lts min FOR CONDENSING BOILERS ONLY CONFIRM THE FOLLOWING THE CONDENSATE DRAIN HAS BEEN INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS YES FOR ALL INSTALLATIONS C...

Page 11: ...GI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 3 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 5 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SIGNATURE SERVICE 6 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID CARD SERIAL No COMMENTS SI...

Page 12: ... the event of a boiler shut down check this is not caused by lack of electricity supply gas supply or low water pressure before calling our Customer Service Helpline Lichfield Road Branston Industrial Estate Burton Upon Trent Staffordshire DE14 3HD Tel 08707 282 885 Fax 08707 282 886 Should you require any assistance during the installation call our Technical Service Helpline on 08707 282 885 opti...

Reviews: