Baffles
Boiler operation requires fitting the baffles supplied with the unit, according to that given
in the following tables.
Before inserting the fume exhaust pipe, check the presence of the right baffle (when it is to
be used) and that it is correctly positioned. The boilers are fitted standard with the smallest
diameter baffle. To replace the baffle (ref. 1 - fig. 10), proceed as indicated in fig. 10.
fig. 10
Connection with coaxial pipes
Standard coaxial installation
fig. 11 - Standard coaxial installation
Other connections coaxial
fig. 12 - Examples of connection with coaxial pipes (
= Air /
= Fumes)
For coaxial connection, fit the unit with one of the following starting accessories. For the
wall hole dimensions, refer to the figure on the cover. Anyhorizontal sections of the fume
exhaust must be kept slopingslightly towards the outside, to prevent possible conden-
sate from flowing back towards the unit.
fig. 13 - Starting accessory for coaxial ducts
Table. 2 - Baffles for coaxial ducts
Connection with separate pipes
fig. 14 - Examples of connection with separate pipes (
= Air /
= Fumes)
For the connection of separate ducts, fit the unit with the following starting accessory:
fig. 15 - Starting accessory for separate ducts
Before proceeding with installation, check the baffle to be used and make sure the max-
imum permissible length has not been exceeded, by means of a simple calculation:
1.
Completely establish the layout of the system of split flues, including accessories
and outlet terminals.
2.
Consult the table 4 and identify the losses in m
eq
(equivalent metres) of every com-
ponent, according to the installation position.
3.
Check that the sum total of losses is less than or equal to the maximum permissible
length in table 3.
Table. 3 - Baffles for separate ducts
Table. 4 - Accessories
3.7 Condensate drain connection
The boiler is equipped with an internal trap for condensate draining. Fit the inspection
union
A
and the flexible tube
B
, pressing it on about 3 cm. Fill the trap with approx. 0.5 l
of water and connect the flexible tube to the drainage system.
fig. 16 - Condensate drain connection
Coaxial 60/100
Coaxial 80/125
Max. permissible length
6 m
12 m
Reduction factor 90° bend
1 m
0.5 m
Reduction factor 45° bend
0.5 m
0.25 m
Baffle to use
0 ÷ 2 m
Ø 45
0 ÷ 6 m
Ø 45
2 ÷ 4 m
Ø 50
6 ÷ 12 m
no baffle
4 ÷ 6 m
no baffle
1
125
200
200
80
400
700
Ø100
125
196
80
330
700
Ø100
Drill the wall 10÷20 mm
more than the
pipe diameter
Rear outlet
Side view
Side outlet
Front view
Between
10 e 60 mm
Between
10 e 60 mm
010007X0
1KWMA56W
C
12
C
12
C
32
C
32
C
32
C
12
010014X0
010006X0
010007X0
80
100
60
125
68
11
8
123.5
45.6
100
60
Separate ducts
Max. permissible length
55 m
eq
Baffle to use
0 ÷ 15 m
eq
Ø 45
15 ÷ 35 m
eq
Ø 50
35 ÷ 55 m
eq
No baffle
Losses in m
eq
Air
inlet
Fume exhaust
Vertical
Horizontal
Ø 80
PIPE
1 m M/F
1KWMA83W
1.0
1.6
2.0
BEND
45° M/F
1KWMA65W
1.2
1.8
90° M/F
1KWMA01W
1.5
2.0
PIPE SECTION
with test point
1KWMA70W
0.3
0.3
TERMINAL
air, wall
1KWMA85A
2.0
-
fumes, wall with antiwind
1KWMA86A
-
5.0
FLUE
Split air/fumes 80/80
1KWMA84U
-
12.0
C
52
C
32
C
52
B
22
C
12
Ø 81
Ø 81
Ø
65
Ø
87
Ø
65