7
DOMIcompact F 24 D
Switching off the boiler. Switching between summer and winter operation has priority over the
heating only time control (optional) when this is connected to the boiler.
C.H. temperature setting
To set the system delivery temperature, turn the knob (ref.
1
- Fig. 1).
It can vary from a minimum of 30 °C to a maximum of 85°C; however, it is advisable not to operate the
boiler below 45 °C. When the knob is turned the display lights up, the radiator symbol flashes and the
temperature displayed will be the temperature actually set. On completing this operation, the display
will stay on for another 5 seconds and then go back to the actual operating temperature providing
there is a demand.
Domestic Hot water temperature adjustment
To set the tap water temperature, turn the knob (ref.
2
- Fig. 1).
It can vary from a minimum of 40 °C to a maximum of 55 °C. When the knob is turned the display lights
up, the tap symbol flashes and the temperature displayed will be the temperature actually set. On
completing this operation, the display will stay on for another 5 seconds to then go back to the actual
operating temperature providing there is a demand.
If the boiler is connected to the optional remote open therm control, the above adjustments
(system and hot water temperature) can only be made with the remote control.
ECO/COMFORT selection
The unit is equipped with a special internal device that ensures a high hot-water delivery speed and
excellent user comfort. When comfort mode is active the water in the boiler is maintained at a pre-
determined temperature, which means that hot water is available at the boiler outlet as soon as a tap
is opened, ie with no waiting.
The user can turn the device off (ECO mode) by pressing the multi-function button for 2 seconds with
the boiler on standby. In ECO mode the display shows the relevant symbol. To turn on COMFORT mode,
press the multi-function button again for 2 seconds, the ECO symbol will vanish from the display.
TEST MODE selection
Pressing the multi-function button 3 times in 3 seconds turns on TEST mode (the heating and hot
water symbols flash simultaneously - see par. 3.1). If TEST mode is turned on by accident, press
the button 3 times in 3 seconds again to exit (Test time 15 minutes unless cancelled early).
Summary of Contents for DOMIcompact F 24 D
Page 39: ......