FERROLI S.p.A.

Via Ritonda 78/a

37047 San Bonifacio - Verona - ITALY

www.ferroli.it

Summary of Contents for BLUEHELIX TECH S 45H

Page 1: ...E ES INSTRUCCIONES DE USO INSTALACIÓN Y MANTENIMIENTO TR KULLANMA KURULUM VE BAKøM TALIMATLARø EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE FR INSTRUCTIONS D UTILISATION D INSTALLATION ET D ENTRETIEN RO INSTRUCğIUNI DE UTILIZARE INSTALARE ùI ÎNTRETINERE RU ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ UA ȱɇɋɌɊɍɄɐȱə Ɂ ȿɄɋɉɅɍȺɌȺɐȱȲ ɆɈɇɌȺɀɍ ɌȺ ɈȻɋɅɍȽɈȼɍȼȺɇɇə ...

Page 2: ...ons premix condensing heat generator with heat exchanger in steel and incorporated DHW production running on natural gas or LPG and equipped with a microprocessor control system The sealed chamber unit is suitable for indoor installation or outdoors in a partially pro tected place according to EN 297 A6 with temperatures to 5 C A The boiler is arranged for connection to an external storage tank fo...

Page 3: ...d the boiler will keep the system at the set system delivery setpoint temperature Room temperature adjustment with optional remote timer control Using the remote timer control set the required temperature in the rooms The boiler will adjust the system water according to the required room temperature For operation with remote timer control please refer to the relevant instruction manual Hot water t...

Page 4: ... on the unit fig 12 Plumbing connections 1 System delivery Ø 3 4 3 Gas inlet Ø 1 2 5 System return Ø 3 4 Antifreeze system antifreeze fluids additives and inhibitors When necessary antifreeze fluids additives and inhibitors can be used only if the man ufacturer of such fluids or additives guarantees that they are suitable and do not cause damage to the exchanger or other components and or material...

Page 5: ...connections terminal block fig 14 The layout of the terminals for the various connections is given in the wiring diagram in fig 29 fig 14 Accessing the terminal block 3 6 Fume ducts Important The unit is type C with sealed chamber and forced draught the air inlet and fume outlet must be connected to one of the following extraction suction systems Before installation check and carefully observe the...

Page 6: ...nd check the tightness of the connection 6 Apply the label contained in the conversion kit near the data plate 7 Refit the front panel 8 Modify the parameter for the type of gas put the boiler in standby mode press the DHW buttons details 1 and 2 fig 1 for 10 seconds the display shows b01 flashing press the DHW buttons details 1 or 2 fig 1 to set parameter 00 for operation with natural gas or 01 f...

Page 7: ...ystem DHW circuits connections or boiler Check correct connection of the electrical system and efficiency of the earthing system Make sure the gas pressure for heating is that required Make sure there are no flammable liquids or materials in the immediate vicinity of the boiler Checks during operation Switch the unit on Check the tightness of the fuel circuit and water systems Check the efficiency...

Page 8: ...traction duct safety device intervention Fault F07 generated 3 times in the last 24 hours See fault F07 A05 Fan protection activated Fault F15 generated for 1 hour consecutive See fault F15 OK NO A06 No flameafter ignitionstage 6 times in 4 minutes Ionisation electrode fault Check the position of the ionisation electrode and replace it if necessary Flame unstable Check the burner Gas valve Offset ...

Page 9: ...Auxiliary contact 104 Fuse 114 Water pressure switch 193 32 114 14 36 186 81 95 278 10 7 11 44 191 196 22 16 0 1 2 3 4 5 6 7 0 500 1 000 1 500 2 000 Q l h H m H2O A 8 9 C B 2 500 Data Unit BLUEHELIX TECH S 45H Max heating capacity kW 43 0 Q Min heating capacity kW 7 5 Q Max Heat Output in heating 80 60 C kW 4 P Min Heat Output in heating 80 60 C kW 7 3 P Max Heat Output in heating 50 30 C kW 4 Min...

Page 10: ...ĨĨŝĐŝĞŶĐLJ Ăƚ ϯϬй ŽĨ ƌĂƚĞĚ ŚĞĂƚ ŽƵƚƉƵƚ ĂŶĚ ůŽǁͲƚĞŵƉĞƌĂƚƵƌĞ ƌĞŐŝŵĞ ΎΎͿ ƚ ĨƵůů ůŽĂĚ ƚ ƉĂƌƚ ůŽĂĚ Ŷ ƐƚĂŶĚďLJ ŵŽĚĞ ƚĂŶĚďLJ ŚĞĂƚ ůŽƐƐ ŐŶŝƚŝŽŶ ďƵƌŶĞƌ ƉŽǁĞƌ ĐŽŶƐƵŵƉƚŝŽŶ ŶŶƵĂů ĞŶĞƌŐLJ ĐŽŶƐƵŵƉƚŝŽŶ ŽƵŶĚ ƉŽǁĞƌ ůĞǀĞů ŵŝƐƐŝŽŶƐ ŽĨ ŶŝƚƌŽŐĞŶ ŽdžŝĚĞƐ dƌĂĚĞŵĂƌŬ ZZK ŽŶĚĞŶƐŝŶŐ ďŽŝůĞƌ z ŽǁͲƚĞŵƉĞƌĂƚƵƌĞ ďŽŝůĞƌ ΎΎͿ EK ϭ ŽŝůĞƌ EK ŽŵďŝŶĂƚŝŽŶ ŚĞĂƚĞƌ EK ŽŐĞŶĞƌĂƚŝŽŶ ƐƉĂĐĞ ŚĞĂƚĞƌ EK ΎͿ ŝŐŚͲƚĞŵƉĞƌĂƚƵƌĞ ƌĞŐŝŵĞ ŵĞĂŶƐ ϲϬΣ ƌĞƚƵƌŶ ƚĞŵƉĞƌĂ...

Page 11: ...ontrol 278 T T 32 191 N L 186 44 114 139 72 230Vac 50Hz LC32 3 2 1 95 16 PWN GND 256 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 3 4 5 6 1 2 5 1 GND Vcc TACHO PWM 1 3 104 FUSE 3 15A 250V ABM03C 81 T1 X4 X3 X2 X1 18 12 1 2 1 1 1 X6 24 230V 1 2 A 155 10 k 1 8 k 138 cod 3541G102 Rev 0 0 2016 ...

Page 12: ...rettiva Bassa Tensione 2006 95 Direttiva Compatibilità Elettromagnetica 2004 108 Presidente 3DROD Ferroli IT Uygunluk beyani ømalatçi FERROLI S p A Adres Via Ritonda 78 a 37047 San Bonifacio VR bu cihazin asagida yer alan AET EEC yönergelerine uygunluk içinde oldugunu beyan etmektedir 2009 142 Gazla çalistirilan üniteler için Yönetmelik QHUJH U3 Yönerge 2006 95 Düsük Voltaj 2004 108 Elektromanyeti...

Page 13: ...FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli it ...