5. TECHNICAL DATA AND CHARACTERISTICS
fig. 27 - General view
Table. 9 - Key of figures cap. 5
fig. 28 - Water circuit
A42
Heating sensor fault
Sensor damaged
Replace the sensor
F43
Exchanger protection
activation.
No system H
2
O circula-
tion
Check the circulating pump
Air in the system
Vent the system
F52
Heating sensor fault
Sensor damaged
Replace the sensor
A61
Controller
ABM03
fault
Controller
ABM03
inter-
nal error
Check the earth connection and
replace the controller if necessary.
A62
No communication
between controller and
gas valve
Controller not connected
Connect the controller to the gas
valve
Valve damaged
Replace the valve
A63
F64
A65
F66
Controller
ABM03
fault
Controller
ABM03
inter-
nal error
Check the earth connection and
replace the controller if necessary.
A23
A24
F20
F21
A26
F40
F47
Card parameter fault
Wrong card parameter
setting
Check the card parameter and modify
it if necessary.
7
Gas inlet
114
Water pressure switch
10
System delivery
138
External probe (optional)
11
System return
139
Remote timer control (optional)
14
Safety valve
154
Condensate drain pipe
16
Fan
155
Hot water tank temperature probe
32
Heating circulating pump
186
Return sensor
36
Automatic air vent
191
Fume temperature sensor
44
Gas valve
193
Trap
56
Expansion tank
196
Condensate tray
72
Room thermostat (not supplied)
209
Hot water tank delivery
74
System filling cock
210
Hot water tank return
81
Ionisation/ignition electrode
278
Double sensor ( Heating)
95
Diverter valve
340
Bypass pipe
104
Fuse
350
Fan/Burner assembly
Fault code
Fault
Possible cause
Cure
10
209 7
210
11
44
193
32
114
14
36
186
56
191
196
350
81
95
278
74
340
10
11
14
114
186
278
56
36
193
154
32
74
95
209
210
cod. 3541C617 - Rev. 02 - 07/2014