Manuale utente
pag. 11 / 15
Mod.200-260 LT
Fig. 4a – Resetting of safety thermostat
Mod.160-200-260 HT
Fig. 4b – Resetting of safety thermostat
For the mod. 90
Disconnect the device from the mains power
supply;
Remove the lower panel by undoing the
appropriate locking screws (Fig. 5);
Remove the water inlet and outlet pipes and
the condensate drain pipe;
Manually reset the tripped safety thermostat
(Fig. 6);
Reassemble the metal panel that was
previously removed.
Restore the water supply connections
replacing the gaskets.
Fig. 5 – Lower panel removal
Fig. 6 – reset of the safety thermostat
WARNING! The tripping of the safety
thermostat can be caused by a fault
linked to the control board or by the
absence of water inside the tank.
WARNING!
Carrying out repair
operations on parts that perform safety
functions jeopardises the safe
operation of the equipment. Substitute
the faulty elements only with original
spare parts.
N.B.: The intervention of the thermostat
excludes the operation of the electric
heating elements but not the heat
pump system within the permitted
operating limits.