BlueHelix HiTech RRT C
36
EN
cod. 3541V691 - Rev. 00 - 04/2022
* Restore Factory Values
To restore all the parameters to the factory values, set parameter
b29
to
10
and confirm. Turn the power off for 10 se-
conds and then back on.
At this point it is necessary to restore parameter
b02
and the modified parameters to the correct value according to the
type of boiler. Parameter
b27
will be automatically set to
5
.
Display Adjustment Menu [DISPLAY]
Here it is possible to set some display parameters.
[Contrast]
Contrast adjustment.
[Brightness]
Brightness adjustment
[Backlight time]
Display backlight duration.
[Reset]
Restore factory values.
fig. 43
P62
Fan minimum speed
DO NOT MODIFY
(The parameters are automatically updated)
G20/G230:
24 kW = 47
28 kW = 47
34 kW = 49
G30/G31:
24 kW = 49
28 kW = 49
34 kW = 48
P63
Fan on speed
DO NOT MODIFY
(The parameters are automatically updated)
G20/G230:
24 kW = 160
28 kW = 160
34 kW = 140
G30/G31:
24 kW = 152
28 kW = 152
34 kW = 132
P64
Fan maximum speed
DO NOT MODIFY
(The parameters are automatically updated)
G20/G230:
24 kW = 140
28 kW = 172
34 kW = 194
G30/G31:
24 kW = 134
28 kW = 156
34 kW = 186
P65
Not implemented
--
1
P66
Valve frequency
0 ÷ 2
1
P67
Installation C(10)3/C(11)3
0 - 1 (1 = installation C(10)3 / C(11)3)
0
P68
Flue parameter
0 ÷ 10 (modify according to flue table)
0
P69
Heating hysteresis after ignition.
(available from MAIN and DSP
FW 1.03)
6 ÷ 30 °C
10
Index
Description
Range
Default
DISPLAY
Contrast
Brightness
Backlight time
Reset
4
Max
1m