25
© Ferno s.r.l.. Rel.18092019
Eagle Nest 3
The Eagle Nest has been submitted to a dynamic resistance and integrity test. This table shows the peak displacement
values. These data allow the user to calculate the minimum air draught under their feet so that any impact is avoided
on the way down. Keep in mind the following data.
Leg configuration
Peak strength
(kN)
Maximum deflection
(mm)
Residual deflection
(mm)
Symmetrical
12
40
30
Asymmetrical
12
35
23
INSPECTION SHEET
DEVICE INSPECTION SHEET
IDENTIFICATION
Product:
Eagle Nest 3
Manufacturer:
FERNO
Purchased on:
First used on:
Expiry date:
Year of manufacture:
Serial number:
Batch number:
User:
Company:
INSPECTION CHECK-LIST
If one of the following problems occurs the EAGLE NET must be temporarily dismissed:
p.
Identification data of the device cannot be read (e.g. serial number)
q.
Not all components are available at the same time as required by the information sheet
r.
The movement of the feet in the different ranges is blocked or even only limited
s.
Presence, even partial, of corrosion or dirt
t.
Signs of corrosion or contact with chemical reagents, solvents or fuels, especially on the textile parts
u.
The base rope is not completely efficient
NOTE THE DEVICE CAN ONLY BE USED AGAIN AFTER THE PROBLEM HAS BEEN SOLVED.
If one of the following defects occurs, the EAGLE NEST must be discontinued:
w.
Presence of dents or signs of perforation, even minimum, in the leg tubes
x.
Presence of deformations which could alter the alignment of tubes composing the legs
y.
Difficult or impossible insertion or extraction of the locking pins
z.
Excessive play of the elements in the insertion points
aa.
Signs of corrosion or contact with chemical reagents, solvents or fuels which could reduce resistance
bb.
Modifications not authorized by the Manufacturer
cc.
In case of a serious fall or after any stress higher than the declared capacity