Before proceeding with the loading or unloading of the 

stretcher, the two operators must always be prepared to 

support the weight of the stretcher and patient, and also for 

the possibility of a "back off" phase, and any other connected 

equipment. Make sure you have applied the restraints and 

that the patient is correctly secured.
To load or unload the stretcher, proceed as follows:

• TO LOAD THE STRETCHER

Lift the front frame, folding it back into the horizontal 

position and that it is in the "folded" position. Carry the 

stretcher to the loading door of the ambulance, ensuring it is 

perpendicular to the entrance; this manoeuvre must always 

be performed by two operators guiding the stretcher. 
1. 

Head-end operator

: Assists the foot-end operator, 

holding the central tube with palms facing up while aligning 

with the loading bay. (Figure 16).
2. 

Head-end operator: 

After verbal contact with his 

colleague, push the stretcher onto the loading level after 

ascertaining that the loading wheels are supported beyond 

the initial ramp.
3. 

Foot-end operator

: Operate the safety lever, located 

below the patient level, to the right.
4. 

Foot-end operator

: Press the right-hand lever to lock the 

front legs (head end). Pushing the weight of the stretcher 

into the ambulance until the rear legs come into contact 

with the back of the vehicle. 

(We recommend both operators 

working simultaneously to reduce the possibility of spinal 

damage).

5. 

Both operators:

 Position at the foot end and proceed 

together with the loading of the stretcher (Figure 17), 

pushing it up to complete the loading of the stretcher into 

the ambulance.
6. After loading the stretcher, be sure to lock the stretcher 

inside the ambulance using the SLAM locking system.

• UNLOADING THE STRETCHER

1. Release the SLAM stretcher locking system
2. 

Head end operator

: Stand beside the stretcher to the 

side, palms facing upwards on the central tube, and assist 

the foot-end operator.
3. 

Foot end operator

: With both hands, grasp the frame 

with palms facing upward, and start pulling the stretcher out 

of the ambulance. Ensure the rear legs open fully and are 

resting against the ground. 

(We recommend unloading one 

at a time to reduce possibility of spinal damage).

** 

Figure 16 - Position of the operators for the loading 

the stretcher

** 

Figure 17 -Loading and / or unloading

the stretcher

** 

Figure 18 - Loading and / or unloading

the stretcher

Head End

Foot End

Summary of Contents for 26-S

Page 1: ...User and Maintenance Manual 26 S Self loading Stretcher Rel 241115 English Readthismanual carefullyandkeepit forfuturereference...

Page 2: ...In case of change of ownership ensure that the manual remains with the product Additional free copies can be obtained from Ferno Washington Italia s Customer Services Intellectual Property Declaration...

Page 3: ...etherestraintscancausethepatienttofallandendanger their safety Always use the restraints to secure the patient Casual assistants may cause damage and or physical harm or injure themselves Do not allow...

Page 4: ...ading stage of the stretcher the operator at the foot end of the patient and any helpers must support the weight of the stretcher the patient and the equipment used in order to allow the legs of the s...

Page 5: ...ppropriate skills to assist the patient Training Operators are required to read and understand all information in this manual attend a suitable training course on the use of the stretcher practice wit...

Page 6: ...ailable locking systems see Accessories WARNING Improper use of the stretcher can cause damage and or injury Use the 26 S stretcher as described in this manual STRETCHER COMPONENTS Head end carrying h...

Page 7: ...Shockproof frame Foot end carrying handle Leg locking system Safety rod Control levers USER AND MAINTENANCE MANUAL To request additional free copies of the instructionmanual contactFernoWashington It...

Page 8: ...e lower part of the floor level wheels The weight of the stretcher does not include mattress and restraints The load limit includes the weight of the stretcher the patient the equipment and in some si...

Page 9: ...thestretcherfromtheambulance the operators use one lever at a time making sure to use the stretcher as described in this instruction manual Safety rod The safety rod is placed under the patient on the...

Page 10: ...ystem integrated brake section The design protects the wheels from dirt and liquid ingress Integrated brake system The brake prevents accidental movement of the stretcher Figure 12 while transferring...

Page 11: ...ion Release the lever and lift the backrest slightly to lock it into position Readjust the restraints 7C Figure 7 A Backrest B unlocking lever action Important Do not use the side rails to lift the st...

Page 12: ...ways standing at the foot end at the side TO LIFT THE FRAME 1 Detach or loosen the restraints holding the legs and waist of the patient Raise the frame to the desired position Figure 10B locking it in...

Page 13: ...r correct locking To operate the leg locking bar Push the bar handle to the bottom to ensure that while loading patient the bar is not bent and therefore no longer functional 14A 14B WARNING Do not op...

Page 14: ...assist the patient and never leave the patient alone during operations involving the stretcher When changing the height position of the stretcher or while unloading it from the ambulance make sure the...

Page 15: ...tube with palms facing upwards and operate the control handles while supporting the weight Push the control handles and lower the stretcher with coordinated movements to the desired height While keep...

Page 16: ...rator Operate the safety lever located below the patient level to the right 4 Foot end operator Press the right hand lever to lock the front legs head end Pushing the weight of the stretcher into the...

Page 17: ...Raising and Lowering section so that it is positioned level with the patient 2 Lock the rear wheels by pressing down brake lever with the foot To lock the rear wheels see Integrated brake system Trans...

Page 18: ...g handle and proceed with patient transport 5 Head end operator assist the foot end operator helping maintain control of the stretcher and checking its path Additional assistance Use of the stretcher...

Page 19: ...ass the belt below the supporting bar placed in proximity of the ABS plastic slot designed for the purpose on the surface Fig 1 2 Pass them through the mattress via the pre spaced eyelets if the mattr...

Page 20: ...Fasten the belt by passing the metal buckle to L joints and insert it into the hook buckle until it locks into position fig 1 3 Always ensure the buckle is fastened To release the restraint 1 Press t...

Page 21: ...leaning Transport restraints To disinfect transport restraints use a disinfectant and follow the manufacturer s instructions To clean the restraints 1 Immerse them in warm disinfected water 2 Rinse th...

Page 22: ...ment that is dry and protected from direct sunlight WARNING Improper maintenance may cause serious accidents injuries and or damage Perform maintenance as instructed in this user manual Routine and pr...

Page 23: ...ont and rear working properly Is the rear leg locking system loose Are the front and rear leg control handles working correctly Are the restraints and mattress in good condition with no cuts or frayed...

Page 24: ...uthorised by Ferno Washington Italia TECHNICAL SUPPORT WARNING Non original spare parts and inadequate repairs may cause damage and or injury Use only Ferno original parts and contact only Ferno Washi...

Page 25: ...trademark are covered by the warranty of the original manufacturer Ferno Washington Italia s r l does not extend the periods of warranties of other manufacturers Ferno Washington Italia s r l assumes...

Page 26: ...ler or to Ferno Washington Italia s r l s Customer Service within 5 days of receipt of the product or of discovery of the alleged defect Claims or disputes regarding a single product does not release...

Page 27: ...27 Ferno Washington Italia 26 S Rel 241115 ENG 26 S Self loading Stretcher TRAINING RECORD Date Instructor Name Training Type MAINTENANCE RECORD Date Type of Maintenance Maintenance Technician...

Page 28: ...508 E mail info ferno it Website www ferno it Product User and Maintenance Manual required to operate the product safely maintain its efficiency and reliability and ensure the validity of the warranty...

Reviews: