PROGRAMMING GUIDE
1.1.- ACCESS CONTROL
Every panels with keypad, includes a basic access control function allowing
users open the door by entering a 4 digits code.
In order to use this function it must have been previously enabled and once in
use there is no way to disable the function (this means that there will always be
a door opening code, known by users or not).
Activation sequence
1.-Power down the system and make a short between “BS” and “-” terminals
of the amplifier (or press the indoor opening pushbutton if installed).
2.-Power up the system and remove the short. There is only a single minute
to enable the opening code.
3.-Dial programming code 3 1 4 1 (this code cannot be modified) and dial the
desired code (four digit code) to open the door and press
.
Changing the code
Previous code must be known in order to change it (when unknown, the activation
sequence must be repeated to store the new one).
The sequence:
1.- dial the programming code: 3 1 4 1
2.- dial the opening code to change
3.- dial the new opening code and press
.
REMARKS:
Dial ‘a’ to erase or restart the dialling sequence
Ensure the short between “BS” and “-” has been removed before closing the
outdoor panel
EN
PROGRAMMING GUIDE
1.1.- ACCESS CONTROL
Every panels with keypad, includes a basic access control function allowing
users open the door by entering a 4 digits code.
In order to use this function it must have been previously enabled and once in
use there is no way to disable the function (this means that there will always be
a door opening code, known by users or not).
Activation sequence
1.-Power down the system and make a short between “BS” and “-” terminals
of the amplifier (or press the indoor opening pushbutton if installed).
2.-Power up the system and remove the short. There is only a single minute
to enable the opening code.
3.-Dial programming code 3 1 4 1 (this code cannot be modified) and dial the
desired code (four digit code) to open the door and press
.
Changing the code
Previous code must be known in order to change it (when unknown, the activation
sequence must be repeated to store the new one).
The sequence:
1.- dial the programming code: 3 1 4 1
2.- dial the opening code to change
3.- dial the new opening code and press
.
REMARKS:
Dial ‘a’ to erase or restart the dialling sequence
Ensure the short between “BS” and “-” has been removed before closing the
outdoor panel