3.5 Advanced Settings 

SIP EXTENSION

:

 

Enable or disable sip extension function. The SIP extension is used as the 

extension of the Guard Unit. When the panel or monitor call the Guard Unit, the SIP extension 

will ring too. If the Guard Unit or SIP extension answer the call, the rest of terminals will stop 

ringing. The maximum amount of SIP extensions is 2. 

URL

: sip: sip account @IP address of sip server 

RTSP

: Enable or disable RTSP function. When the guard unit calls to a monitor or to other 

guard unit, the associated IP CCTV RTSP video stream will be displayed on the monitor or 

guard unit. 

URL

: rtsp://user:password@IP address of camera 

This is the CCTV RTSP video stream that will be associated to the guard unit. User and 

password: for cameras that require a username and password for connection, these fields are 

optional. 

 

3.6 Unlock Settings 

DTMF UNLOCK

:

 

Enables or disables DTMF unlock function. 

DTMF KEY

: Characters required to be entered when the guard unit releases the lock on a SIP 

panel , such as # or *. The characters to release the lock can also be set up in the SIP panel. 

The guard unit will send characters to release the lock on SIP panel, when the concierge 

presses the door open icon. 

HTTP UNLOCK

: Enable or disable HTTP unlock function. 

The system will send a http request when the guard unit release lock. 

URL

: Open the door lock via URL. The guard unit will send web address tor release the lock 

from a SIP panel when the concierge presses the door open icon. The URL can be set up in 

the SIP panel 

Summary of Contents for MEET GUARD UNIT

Page 1: ...MEET GUARD UNIT INSTALLER S MANUAL ENGLISH Version Cod 970136Ib V09_18 This manual corresponds to MEET Guard Unit firmware version V2 0...

Page 2: ...com MEET Guard Unit manual available at https www fermax com qr meet Copyright Notice Fermax and Fermax MEET guard unit are trademarks of Fermax Electronica S A U registered in the European Union and...

Page 3: ...2 8 Ringtone Setting 9 2 9 Date Time Setting 9 2 10 Language Setting 10 2 11 Screen Setting 10 2 12 About 11 3 Configuration via Web Server 12 3 1 Device Information 12 3 2 General Settings 13 3 3 Ne...

Page 4: ...Page 4 1 Product Introduction 1 1 Overview 1 1 Guard Unit Interface Handset Alarm notification LED Touch screen Base Network Status...

Page 5: ...automatically or record manually the audio from monitor 2 1 Call Receptions The MEET Guard Unit can receive calls from Outdoor panels Monitor call Other guard units from the same installation The guar...

Page 6: ...ilable During the call the guard unit is able to record the conversation s audio for later review SD card required 2 3 Call Guard Unit Guard units can call each other if required To call a guard unit...

Page 7: ...if applied REMARK The call log relates only to calls sent or received from the Guard unit No call logs from panel to monitor calls or apartment to apartment 2 6 Alarm Log The LED and siren alarm on th...

Page 8: ...nction Setting The functions restrictions interface is used to activate or deactivate functions CAMERA no use in this version VIDEO RECORD AUDIO RECORD Function During the call the guard unit is able...

Page 9: ...installed the installer can set date time and time zone manually If the project has MEET management software and it is not connected to internet the date and time of guard unit will synchronize autom...

Page 10: ...lect the guard unit s operating language in the language settings menu REMARK The guard unit will reboot automatically language is selected 2 11 Screen Setting The user can adjust brightness and contr...

Page 11: ...Page 11 2 12 About In this option is it possible to access to the following information device name firmware version MAC address IP address...

Page 12: ...accessed via the guard unit s IP address The browser opens with the configured IP address of the Guard Unit A screen opens requesting username and password REMARK Default IP 10 201 100 0 Username admi...

Page 13: ...with the same guard unit number between 0 and 7 default option 0 Guard units with the same GUARD NO but different DEVICE NO will ring at the same time REMARK The device number of guard unit must be 0...

Page 14: ...of PC where MEET management software is installed default option 10 0 0 200 SW PIN The pin code is to be used when the panel is registered in MEET management software NTP IP IP address of NTP server...

Page 15: ...public network server IP STUN PORT The port of audio and video NAT traversing public network server SIP USER The username of sip account SIP PASS The password of sip account CONVERSATION Conversation...

Page 16: ...TV RTSP video stream that will be associated to the guard unit User and password for cameras that require a username and password for connection these fields are optional 3 6 Unlock Settings DTMF UNLO...

Page 17: ...Page 17 3 7 Pincode Settings This allows to change the pin code of the web server login 3 8 Log Out Log out the web server...

Page 18: ...e 18 4 Installation 4 1 Schematic Diagram of Guard Unit Installation 1 Fit support on the base 2Support installation Assembly direction 3Display screen is stuck from up and down 4Installation is compl...

Page 19: ...unit Take down the direction 1The display screen is removed from the bottom up from the bracket Use a screwdriver to force the direction of the arrow angle can be separated from the bracket and a bas...

Page 20: ...al Parameters Power supply 12Vdc Standby current 200mA Working current 500mA Screen 9 inches Resistive touch screen Resolution 800 480 Maximum conversation time 120s Maximum record time 30s Guard unit...

Reviews: