Page 14
3.3 Network Settings
MEET allows the installer to define the IP range according to the project needs and make the
network management easier. MEET panel network mode is static mode. Ensure that each
device has a unique IP address in same installation. The devices (digital panel, monitor and
guard unit) will show IP conflict if there same IP is used on the same LAN.
IP
: IP address of the guard unit (default option 10.201.100.0).
MASK
: Subnet mask of the guard unit (default option 255.0.0.0).
GATEWAY
: Default gateway of the guard unit (default option 10.254.0.1).
DNS
: DNS of the guard unit (default option 8.8.8.8).
SOFTWARE IP
: IP address of PC where MEET management software is installed. (default
option 10.0.0.200).
SW. PIN
: The pin code is to be used when the panel is registered in MEET management
software.
NTP IP
: IP address of NTP server.
If the project has no MEET management software installed, the installer can set date, time and
time zone manually. If the project has MEET management software, and it is not connected to
internet, the date and time of guard unit will synchronize automatically with the management
software. If the project has MEET management software and it is also connected to internet,
the date and time of the guard unit will synchronize automatically from internet time server.
NOTE:
The date and time of guard unit will synchronize automatically with internet. A NTP IP
server must be available.The guard unit must be reset after you change NTP IP.