-10-
Door lock controlled with internal power
Power on to unlock. (12V output, up to 250mA).
EB: Exit button (Door lock control is not timed by the exit
button)
Door lock controlled with dry contact
The inside relay contact is restricted to AC or DC 24V/3A.
The jumper must be taken off before connecting
Note: It is advisable to always use a separate power supply
for the electric latch, as well as placing a varistor at both
terminals of the electric latch.
EB: Exit button (Door lock control is not timed by
the exit button)
See Figure 1, press KEY_SET button, then
press KEY_ X once (where X goes from 1-4),
wait 10 seconds or press KEY_SET button
four times to save the settings.
E.G.:
For door station 1: KEY-SET, KEY_1, press
KEY_SET four times.
For door station 2: KEY-SET, KEY_2, press
KEY_SET four times.
Figure 1
6. Electric Lock Connection
5. Programming Door Station address (When using more than one door
station)
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
RF CARD
LOCK
Take off the Jumper
POWER
SUPPLY
BUS
PL
S+
S-
VARISTOR
EB
*
LOCK
BUS
PL
S+
S-
Jumper position in 2-3
1 2 3
VARISTOR